Napoleon Fireplaces GD82PT-T, GD82NT-T manual General Instructions, General Information

Page 4

4

58"

46"

37 5/8"

5"

2"

FIGURE 1

17 3/4"

4" DIA.

7" DIA.

21" 22 1/8"

7/8"

13 7/8"

24"

28"

8 7/8"

14"

28"

GENERAL INSTRUCTIONS

THIS GAS FIREPLACE SHOULD BE INSTALLED AND SER- VICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the specifi cs that apply to your area, for example: in Massachusetts State:

The fi replace damper must be removed or welded in the open position prior to installation of a fi replace insert or gas log.

The appliance off valve must be a “T” handle gas cock.

The fl exible connector must not be longer than 36 inches.

The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product.

A carbon monoxide detector is required in all rooms containing gas fi red appliances.

WARNING: This product must be installed by a licensed plumber or gas fi tter when installed within the commonwealth of Massachusetts.

In absence of local codes, install to the current CAN/CGA -B149 Installation Code in Canada or to the National Fuel Gas Code, ANSI Z223.1, and NFPA 54 in the United States. Suitable for mobile home installation if installed in accordance with the current standard CAN/CSA Z240MH Series, for gas equipped mobile homes, in Canada or ANSI Z223.1 and NFPA 54 in the United States.

The fi replace and its individual shutoff valve must be discon- nected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The fi replace must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

When the fi replace is installed directly on carpeting, vinyl tile or other combustible material other than wood fl ooring, the fireplace shall be installed on a metal or wood panel extending the full width and depth.

The optional heat circulating blower is supplied with a cord. If installed, the junction box must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELEC- TRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.

Purge all gas lines with the glass door of the fireplace open. Assure that a continuous gas flow is at the burner before closing the door.

Under extreme vent configurations, allow several minutes (5-15) for the flame to stabilize after ignition.

Provide adequate ventilation and combustion air.

Provide adequate accessibility clearance for servicing and operating the fireplace. Never obstruct the front opening of the fireplace.

Objects placed in front of the fireplace must be kept a minimum of 48” from the front face of the unit.

Minimum clearance to combustible construction from fireplace and vent surfaces:

fireplace framing

- 0” to stand-offs (top, rear and sides)

fireplace finishing

- 4” from the sides of firebox opening

 

 

21 3/4” to top of fireplace opening.

vent pipe

-

2 inches*

recessed depth

-

22 1/4 inches

*The first 2 feet of outer 7 inch diameter vent pipe from the appliance must be wrapped in the 1” thick insulation sleeve (supplied). There must be a 1” air gap in addition to the insulation. Thereafter a 1” clearance all around the vent pipe is acceptable.

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY! Maximum input is 26,000 BTU/hr for both natural gas and propane. When the fi replace is installed at elevations above 4,500ft, and in the absence of specifi c recommendations from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft. Maximum output for natural gas is 16150 BTU/hr at an efficiency of 62%; and 16150 BTU/hr for propane at an effi ciency of 62%. Minimum inlet gas supply pressure is

4.5inches water column for natural gas and 11 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane. Manifold pressure under flow conditions is 3.5 inches water column for natural gas and 10 inches water column for propane.

W415-0583 / B / 05.23.07

Image 4
Contents Installation Operation Instructions Table of Contents Napoleon GAS Fireplace PRESIDENT’S Lifetime Limited Warranty General Instructions General InformationCare of Glass VentingVenting Lengths & AIR Terminal Locations Definitions TOP Exit / Horizontal TerminationElbow Vent Length Values HT + VT= 10.7 + 6 =16.7 VT = 4.2 x 6 = 25.2 ftSince both formulas are met, this vent confi guration is ac CeptableTOP Exit Vertical Termination TOP Vertical TerminationW415-0583 / B Installation Wall and Ceiling Protection Vertical Installation Horizontal InstallationHorizontal AIR Terminal Installation Using Flexible Vent ComponentsVertical AIR Terminal Installation Using Rigid Vent Components Vertical Venting InstallationExtended Horizontal AIR Terminal Installation Fireplace Vent ConnectionMobile Home Installation GAS InstallationRestricting Vertical Vents Framing Clearance to CombustiblesHard Wiring Connection Electrical SchematicElectrical Connection Mantle ClearancesFinishing / Servicing Blower Replacement Burner Base RemovalBattery Replacement Remove the optional front. Instructions on PgNight Lighttm Replacement Operation / MaintenanceTime OUT Fireplace OperationHand Held Remote Operations Flame HeightAddress Setting Procedure DIP Switch Number 0 = on / 1 = OFF Operating Instructions What to do if YOU Smell GASLighting Instructions To Turn OFF GASAdjustments MaintenancePilot Burner Adjustment Venturi AdjustmentConversion KIT Replacements 000 Trouble Shooting Guide Symptom Problem Test SolutionStanding Main Pilot goes out while Gas piping is undersizedBurner is in ‘OFF’ Supply working pressure Position Fireplace Service History W415-0583 / B
Related manuals
Manual 32 pages 46.04 Kb

GD82NT-T, GD82PT-T specifications

The Napoleon Fireplaces GD82PT-T and GD82NT-T are exquisite additions to any modern home, designed to combine style, efficiency, and advanced technology in one compact unit. These gas fireplaces offer remarkable features that cater to both aesthetic and functional needs, making them an ideal choice for homeowners seeking to enhance their living spaces.

At the heart of the GD82PT-T and GD82NT-T is Napoleon’s innovative burner technology. They utilize a unique PHAZER log set and glowing ember bed, creating a realistic flame effect that captures the essence of a traditional wood-burning fireplace while utilizing the convenience of gas. The stunning lifelike flames dance over the logs, providing ambiance and warmth that transforms any room into a cozy retreat.

One of the standout features of these models is their efficiency. Both the GD82PT-T and GD82NT-T are designed to provide substantial heating output while maintaining a high efficiency rating. The advanced heat distribution system ensures that warmth is evenly spread throughout the room, delivering comfort during colder months without excessive energy consumption.

In addition to their heating capabilities, these fireplaces come with Napoleon's patented Easy Clean glass, which helps minimize soot and residue build-up. This feature not only ensures a clearer view of the flames but also simplifies maintenance, allowing homeowners to enjoy their fireplaces without the hassle of frequent cleaning.

Another notable characteristic of the GD82PT-T and GD82NT-T is their customizable design options. Homeowners can choose from a variety of styles, including contemporary to traditional, with multiple finishes to ensure a perfect match with their existing décor. This versatility allows these fireplaces to seamlessly integrate into any living space while making a bold design statement.

Furthermore, the fireplaces come equipped with a remote control that allows users to adjust the flame height, thermostat settings, and other features with ease. This convenience enhances the overall user experience, providing the ultimate atmosphere at the touch of a button.

Safety is paramount, and Napoleon has incorporated several features to ensure peace of mind. These include an automatic shut-off system and a protective screen barrier, safeguarding against accidental contact with the hot glass.

Overall, the Napoleon Fireplaces GD82PT-T and GD82NT-T are exemplary choices for anyone seeking a perfect blend of beauty, efficiency, and technology. With their innovative design and advanced features, they stand out as premier options in the gas fireplace market, making them worthy investments for comfort and style in any home.