Napoleon Fireplaces GD82PT-T, GD82NT-T manual Adjustments, Maintenance, Pilot Burner Adjustment

Page 24

24

MAINTENANCE

TURN OFF THE GAS AND ELECTRICAL POWER

BEFORE SERVICING THE FIREPLACE.

CAUTION: Label all wires prior to disconnection when servic- ing controls. Wiring errors can cause improper and danger- ous operation. Verify proper operation after servicing. This

replace and its venting system should be inspected before use and at least annually by a qualifi ed service person. The

replace area must be kept clear and free of combustible materials, gasoline or other fl ammable vapours and liquids. The fl ow of combustion and ventilation air must not be ob- structed.

1.In order to properly clean the burner and pilot as- sembly, remove the bowl and rockset to expose both assemblies.

2.Keep the control compartment, bowl and rockset, burner, air shutter opening and the area surrounding the logs clean by vacuuming or brushing, at least once a year.

3.Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning properly.

4.Check to see that the pilot fl ame is large enough to engulf the thermocouple and thermopile and reaches toward the burner with the third jet.

5.Replace the cleaned bowl and rockset.

6.Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5 to 10 second total light-up period is satisfactory. If ignition takes longer, consult your Napoleon® dealer / distributor.

7.Check that the gasketing on the sides, top and bot- tom of the door is not broken or missing. Replace if necessary.

ADJUSTMENTS

PILOT BURNER ADJUSTMENT

Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow.

FIGURE 60

PILOT

SCREW

FIGURE 61

VENTURI ADJUSTMENT

Air Shutter Openings

LP

1/2

NG

3/16

 

Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The flame may not appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame colour to be established.

FIGURE 62

AIR

SHUTTER

OPENING

FLAME CHARACTERISTICS

It is important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustration below.

3/8” - 1/2”

W415-0583 / B / 05.23.07

Image 24
Contents Installation Operation Instructions Table of Contents Napoleon GAS Fireplace PRESIDENT’S Lifetime Limited Warranty General Instructions General InformationVenting Care of GlassVenting Lengths & AIR Terminal Locations TOP Exit / Horizontal Termination DefinitionsElbow Vent Length Values HT + VT= 10.7 + 6 =16.7 VT = 4.2 x 6 = 25.2 ftSince both formulas are met, this vent confi guration is ac CeptableTOP Exit Vertical Termination TOP Vertical TerminationW415-0583 / B Installation Wall and Ceiling Protection Vertical Installation Horizontal InstallationUsing Flexible Vent Components Horizontal AIR Terminal InstallationVertical AIR Terminal Installation Using Rigid Vent Components Vertical Venting InstallationExtended Horizontal AIR Terminal Installation Fireplace Vent ConnectionGAS Installation Mobile Home InstallationRestricting Vertical Vents Framing Clearance to CombustiblesHard Wiring Connection Electrical SchematicElectrical Connection Mantle ClearancesFinishing / Servicing Blower Replacement Burner Base RemovalBattery Replacement Remove the optional front. Instructions on PgNight Lighttm Replacement Operation / MaintenanceTime OUT Fireplace OperationHand Held Remote Operations Flame HeightAddress Setting Procedure DIP Switch Number 0 = on / 1 = OFF Operating Instructions What to do if YOU Smell GASLighting Instructions To Turn OFF GASAdjustments MaintenancePilot Burner Adjustment Venturi AdjustmentConversion KIT Replacements 000 Trouble Shooting Guide Symptom Problem Test SolutionPilot goes out while Gas piping is undersized Standing MainBurner is in ‘OFF’ Supply working pressure Position Fireplace Service History W415-0583 / B
Related manuals
Manual 32 pages 46.04 Kb

GD82NT-T, GD82PT-T specifications

The Napoleon Fireplaces GD82PT-T and GD82NT-T are exquisite additions to any modern home, designed to combine style, efficiency, and advanced technology in one compact unit. These gas fireplaces offer remarkable features that cater to both aesthetic and functional needs, making them an ideal choice for homeowners seeking to enhance their living spaces.

At the heart of the GD82PT-T and GD82NT-T is Napoleon’s innovative burner technology. They utilize a unique PHAZER log set and glowing ember bed, creating a realistic flame effect that captures the essence of a traditional wood-burning fireplace while utilizing the convenience of gas. The stunning lifelike flames dance over the logs, providing ambiance and warmth that transforms any room into a cozy retreat.

One of the standout features of these models is their efficiency. Both the GD82PT-T and GD82NT-T are designed to provide substantial heating output while maintaining a high efficiency rating. The advanced heat distribution system ensures that warmth is evenly spread throughout the room, delivering comfort during colder months without excessive energy consumption.

In addition to their heating capabilities, these fireplaces come with Napoleon's patented Easy Clean glass, which helps minimize soot and residue build-up. This feature not only ensures a clearer view of the flames but also simplifies maintenance, allowing homeowners to enjoy their fireplaces without the hassle of frequent cleaning.

Another notable characteristic of the GD82PT-T and GD82NT-T is their customizable design options. Homeowners can choose from a variety of styles, including contemporary to traditional, with multiple finishes to ensure a perfect match with their existing décor. This versatility allows these fireplaces to seamlessly integrate into any living space while making a bold design statement.

Furthermore, the fireplaces come equipped with a remote control that allows users to adjust the flame height, thermostat settings, and other features with ease. This convenience enhances the overall user experience, providing the ultimate atmosphere at the touch of a button.

Safety is paramount, and Napoleon has incorporated several features to ensure peace of mind. These include an automatic shut-off system and a protective screen barrier, safeguarding against accidental contact with the hot glass.

Overall, the Napoleon Fireplaces GD82PT-T and GD82NT-T are exemplary choices for anyone seeking a perfect blend of beauty, efficiency, and technology. With their innovative design and advanced features, they stand out as premier options in the gas fireplace market, making them worthy investments for comfort and style in any home.