Napoleon Fireplaces GD82NT-T Operating Instructions, What to do if YOU Smell GAS, To Turn OFF GAS

Page 23

23

OPERATING INSTRUCTIONS

When lit for the fi rst time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of paints and lubricants used in the manufactur- ing process and will not occur again. Simply open a window to suffi ciently ventilate the room.

After extended periods of non-operation such as following a vacation or a warm weather season, the fi replace may emit a

FOR YOUR SAFETY READ BEFORE LIGHTING:

A.This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly.

B.Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor.

C.Use only your hand to turn the gas control knob / manual shut-off knob. Never use tools. If the knob will not turn by hand, do not try to repair it. Call a qualifi ed service technician. Force or attempted re pair may result in a fi re or explosion.

D.Do not use this fi replace if any part has been under water. Immediately call a qualifi ed service technician to inspect the fi replace and replace any part of the control system and any gas control which has been under water.

slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to sufficiently ventilate the room.

Purge all gas lines with the glass door of the fireplace open. Assure that a continuous gas flow is at the burner before closing the door.

WHAT TO DO IF YOU SMELL GAS

Do not touch any electric switch.

Do not use any phone in your building.

If you cannot reach your gas supplier, call the fi re department.

Turn off all gas to the fi replace.

Do not try to light any appliance.

Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s instructions.

FIGURE 58

GAS KNOB

LIGHTING INSTRUCTIONS

Warning: if you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. Initial lighting of the pilot and main burners must be done with the glass door off.

Do not connect valve or wall switch to electricity. See insta llation instructions.

When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob it depressed slightly.

1.STOP! read the safety information on the operating label.

2.Turn off all electric power to the fi replace.

3.Turn the gas knob clockwise to off.

4.Wait 5 minutes to clear out any gas. If you smell gas, including near the fl oor, STOP! Follow “B” on the op erating label. If you don’t smell gas, go to the next step.

5.If the fi replace is equipped with a fl ame adjustment valve, turn clockwise to off.

6.Find pilot located in front of the back log on the right side.

7.Turn gas knob counter-clocwise to pilot.

8.This unit is equipped with an auto-spark.

Depress and hold gas knob . Keep knob fully de pressed for one minute, then release. If pilot does not continue to burn repeat steps 3 through 7.

9.With pilot lit, turn gas knob counter-clockwise to on.

10.If equipped with fl ame adjustment valve, push and turn knob to high.

11.If equipped with remote on-off switch, main burner may not come on when you turn the valve to on or high. Remote switch must be in the on position to ignite burner.

12.Turn on all electric power to the fi replace.

FIGURE 59

SOLENOID PILOT

ON/OFF

KNOB

TO TURN OFF GAS

1.Turn off all electric power to the fi replace if service is to be performed.

2.For a complete shut-down procedure: push in gas

control knob slightly and turnclockwise to off. Do not force.

3.For a temporary shut-down procedure: set thermostat to lowest setting or remote switch to off. Press and turn the

gas knob clockwiseto pilot.

W415-0583 / B / 05.23.07

Image 23 Contents
Installation Operation Instructions Table of Contents Napoleon GAS Fireplace PRESIDENT’S Lifetime Limited Warranty General Information General InstructionsVenting Lengths & AIR Terminal Locations VentingCare of Glass Elbow Vent Length Values TOP Exit / Horizontal TerminationDefinitions Ceptable HT + VT= 10.7 + 6 =16.7VT = 4.2 x 6 = 25.2 ft Since both formulas are met, this vent confi guration is acTOP Vertical Termination TOP Exit Vertical TerminationW415-0583 / B Vertical Installation Horizontal Installation Installation Wall and Ceiling ProtectionVertical AIR Terminal Installation Using Flexible Vent ComponentsHorizontal AIR Terminal Installation Fireplace Vent Connection Using Rigid Vent ComponentsVertical Venting Installation Extended Horizontal AIR Terminal InstallationRestricting Vertical Vents GAS InstallationMobile Home Installation Clearance to Combustibles FramingMantle Clearances Hard Wiring ConnectionElectrical Schematic Electrical ConnectionFinishing / Servicing Burner Base Removal Blower ReplacementRemove the optional front. Instructions on Pg Battery ReplacementFireplace Operation Night Lighttm ReplacementOperation / Maintenance Time OUTFlame Height Hand Held Remote OperationsAddress Setting Procedure DIP Switch Number 0 = on / 1 = OFF To Turn OFF GAS Operating InstructionsWhat to do if YOU Smell GAS Lighting InstructionsVenturi Adjustment AdjustmentsMaintenance Pilot Burner AdjustmentConversion KIT Replacements 000 Symptom Problem Test Solution Trouble Shooting GuideBurner is in ‘OFF’ Supply working pressure Position Pilot goes out while Gas piping is undersizedStanding Main Fireplace Service History W415-0583 / B
Related manuals