Martin Fireplaces BV4536 Standing Pilot Ignition Wiring-Millivolt Control, Remote Wall Switch

Page 17

GAS LINE AND ELECTRICAL INSTALLATION

Figure 12: Gas Pressure Check at Gas Valve

Electrical Wiring:

Standing Pilot Ignition Wiring-Millivolt Control:

WARNING

Do not connect 110-120 VAC to the Remote Wall Switch, DC Remote Control or the Millivolt Control Valve.

The appliance will malfunction or the valve will be damaged.

CAUTION

Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service. All wiring shall be in compliance with all local, city, and state codes. The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the

National Electrical Code ANSI / NFPA 70 (latest edition), or the Canadian Electrical Code, CSA C22.1.

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and

dangerous operations. Verify proper operation after servicing.

Remote Wall Switch

Fifteen (15) feet of 18 Ga. wire is provided as standard with this fireplace, that may be routed to a remote wall switch. The wire has been pre-wired at the valve and routed through the right side, outer shell. (Access is also available on the left side through the square hole on that side). Position the wall switch inside of a non-metallic junction box (not provided) at the desired location on the wall. Refer to Figure 13: Wiring Diagram for Standing Pilot - Millivolt System. Do not extend beyond the wall switch wire length provided.

NOTE

Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire is permitted

if the wire is a larger gauge (diameter) wire. Always check with local codes.

16

Image 17
Contents Super B-VENT GAS Fireplace Table of Contents Always Burn Propane Models with Doors Closed Important Safety InformationImportant Safety Information Product Specifications Product SPECIFICATIONS/LISTING & Code ApprovalListing & Code Approval Model LAB Type Certification StandardPRE-INSTALLATION Information PRE-INSTALLATION InformationFireplace Dimensions PRE-INSTALLATION Information Combustible Clearances Mantel Clearance Floor Clearances Mantel ClearancesPRE-INSTALLATION Information Vent Installation Vent InstallationVertical Venting Straight up No Elbow Dim Min Max FeetVertical Venting with Two 2 45 Degree Elbow Installing Vent ComponentsPiping Installations To Locate and Install Ceiling Firestop For Vertical Termination Ceiling Firestop Location Vent TerminationOutside Air Kit Installation To Locate and install Vertical TerminationDo not use open flame to check for gas leaks GAS Line and ElectricalRemote Wall Switch Standing Pilot Ignition Wiring-Millivolt ControlOptional DC Remote Systems Millivolt Control Valve ChecklistThermopile Output Check Complete Millivolt System CheckWiring Diagram for Electronic Ignition System Electronic Pilot Ignition WiringGAS Line and Electrical Installation Definitions Final InstallationLog Placement Log Placement for fiber VDY24/18D3RDoor Rail Installation Damper Operation Hi Temperature Cut Off Disc Before Lighting the Fireplace Operating InstructionsLighting the Fireplace You may notice the followingLighting Instructions Millivolt Control Lighting Instructions Electronic IGN Maintenance MaintenanceStanding-Pilot Flame Only Burner FlameGlass Door Soot cleaning fluid may be used on refractory logsVent System Parts List / Illustration Parts List / IllustrationsConversion Kit Not Shown for MillivolControl Only Conversion Kit Not Shown for Electronic Ignition Page Electronic Ignition General Troubleshooting 41D2001 Rev 3 Dec Limited Lifetime Warranty Policy