PRODUCT SPECIFICATIONS/LISTING & CODE APPROVAL

PRODUCT SPECIFICATIONS:

 

 

 

 

Gas Pressure (Inches W.C.)

Models Number

Gas Type

Control Type

Max Btu

Max

Min

Manifold

 

 

 

 

 

 

 

BV4536NV

Natural Gas

Milli-volt

50000

10.5

4.0

3.5

BV4536PV

Propane/LPG

Milli-volt

50000

13.0

11.0

10.0

BV5142NV

Natural Gas

Milli-volt

50000

10.5

4.0

3.5

BV5142PV

Propane/LPG

Milli-volt

50000

13.0

11.0

10.0

BV4536NE

Natural Gas

Electronic

50000

10.5

4.0

3.5

BV4536PE

Propane/LPG

Electronic

50000

13.0

11.0

10.0

BV5142NE

Natural Gas

Electronic

50000

10.5

4.0

3.5

BV5142PE

Propane/LPG

Electronic

50000

13.0

11.0

10.0

 

 

 

 

 

 

 

High Altitude Installations

Gas rate shown above is for altitudes up to 2000 ft. When installing this fireplace at an elevation above 2000 ft, it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input should be reduced four percent (4%) for each 1000 ft above sea level, unless the heating value of the gas has been reduced. Consult your local dealer or gas authority for assistance in determining the proper orifice at your location.

LISTING & CODE APPROVAL:

The above models have been tested and certified by the applicable laboratories to the standards listed below.

MODEL

LAB.

TYPE

CERTIFICATION STANDARD

BV4536 Series

CSA

Decorative Vented Gas Fireplace

ANSI Z21.50-2000CSA 2.22-2000

BV5142 Series

CSA

Decorative Vented Gas Fireplace

ANSI Z21.50-2000CSA 2.22-2000

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is convertible for use with other gases, when a certified kit is used.

3

Image 4
Contents Super B-VENT GAS Fireplace Table of Contents Important Safety Information Important Safety InformationAlways Burn Propane Models with Doors Closed Product SPECIFICATIONS/LISTING & Code Approval Product SpecificationsListing & Code Approval Model LAB Type Certification StandardPRE-INSTALLATION Information PRE-INSTALLATION InformationFireplace Dimensions PRE-INSTALLATION Information Combustible Clearances Mantel Clearances Mantel Clearance Floor ClearancesPRE-INSTALLATION Information Vent Installation Vent InstallationVertical Venting Straight up No Elbow Dim Min Max FeetPiping Installations Installing Vent ComponentsVertical Venting with Two 2 45 Degree Elbow To Locate and Install Ceiling Firestop Ceiling Firestop Location Vent Termination For Vertical TerminationTo Locate and install Vertical Termination Outside Air Kit InstallationGAS Line and Electrical Do not use open flame to check for gas leaksStanding Pilot Ignition Wiring-Millivolt Control Remote Wall SwitchMillivolt Control Valve Checklist Optional DC Remote SystemsThermopile Output Check Complete Millivolt System CheckElectronic Pilot Ignition Wiring Wiring Diagram for Electronic Ignition SystemGAS Line and Electrical Installation Final Installation DefinitionsLog Placement for fiber VDY24/18D3R Log PlacementDoor Rail Installation Damper Operation Hi Temperature Cut Off Disc Operating Instructions Before Lighting the FireplaceLighting the Fireplace You may notice the followingLighting Instructions Millivolt Control Lighting Instructions Electronic IGN Maintenance MaintenanceStanding-Pilot Flame Only Burner FlameVent System Soot cleaning fluid may be used on refractory logsGlass Door Parts List / Illustrations Parts List / IllustrationConversion Kit Not Shown for MillivolControl Only Conversion Kit Not Shown for Electronic Ignition Page Electronic Ignition General Troubleshooting Limited Lifetime Warranty Policy 41D2001 Rev 3 Dec