Martin Fireplaces BV5142, BV4536 Damper Operation Hi Temperature Cut Off Disc

Page 24

FINAL INSTALLATION

Damper operation:

NOTE

For Massachusetts residents only: Installation of this vented gas fireplace in the Commonwealth of

Massachusetts requires the damper to be permanently removed or welded into the fully open position. In

addition, a naturally vented gas fireplace may not be installed in a bedroom or bathroom in the

Commonwealth of Massachusetts.

1.When damper arm (1) is all the way to the left and locked into position, the damper system is closed. (Refer to Figure 22.)

2.Pull damper arm (1) forward and unlock from closed position by swinging damper arm (1) to the right. (Refer to Figure 22.)

3.Swing damper arm (1) to the right, forcing into the locked position, to open damper system. (Refer to Figure 22.)

WARNING

Damper must be in open position when appliance main burner is operating. The damper system must be LOCKED into the OPEN position during operation. If damper is not open the appliance will shut down at the pilot. See lighting instructions if this occurs.

If damper system is not locked into the open position, the appliance my cause some spillage into the living

area before the temperature switch can shut the pilot off.

Do not install a damper device to the appliance. Only use damper device that comes with the unit

NOTE

Remove damper instruction tag before operating the unit

Figure 22: Damper Operation

Hi Temperature Cut Off Disc:

This unit is equipped with a shut off disc that helps prevent spillage due to a down draft. It also helps prevent operation of the unit with damper closed. The Hi Temp. switch is located on the upper left corner of the fireplace opening. DO NOT OPERATE THE FIREPLACE WITH THE SWITCH BYPASSED

23

Image 24
Contents Super B-VENT GAS Fireplace Table of Contents Important Safety Information Important Safety InformationAlways Burn Propane Models with Doors Closed Product SPECIFICATIONS/LISTING & Code Approval Product SpecificationsListing & Code Approval Model LAB Type Certification StandardPRE-INSTALLATION Information PRE-INSTALLATION InformationFireplace Dimensions PRE-INSTALLATION Information Combustible Clearances Mantel Clearances Mantel Clearance Floor ClearancesPRE-INSTALLATION Information Vent Installation Vent InstallationVertical Venting Straight up No Elbow Dim Min Max FeetInstalling Vent Components Piping InstallationsVertical Venting with Two 2 45 Degree Elbow To Locate and Install Ceiling Firestop Ceiling Firestop Location Vent Termination For Vertical TerminationTo Locate and install Vertical Termination Outside Air Kit InstallationGAS Line and Electrical Do not use open flame to check for gas leaksStanding Pilot Ignition Wiring-Millivolt Control Remote Wall SwitchMillivolt Control Valve Checklist Optional DC Remote SystemsThermopile Output Check Complete Millivolt System CheckElectronic Pilot Ignition Wiring Wiring Diagram for Electronic Ignition SystemGAS Line and Electrical Installation Final Installation DefinitionsLog Placement for fiber VDY24/18D3R Log PlacementDoor Rail Installation Damper Operation Hi Temperature Cut Off Disc Operating Instructions Before Lighting the FireplaceLighting the Fireplace You may notice the followingLighting Instructions Millivolt Control Lighting Instructions Electronic IGN Maintenance MaintenanceStanding-Pilot Flame Only Burner FlameSoot cleaning fluid may be used on refractory logs Vent SystemGlass Door Parts List / Illustrations Parts List / IllustrationConversion Kit Not Shown for MillivolControl Only Conversion Kit Not Shown for Electronic Ignition Page Electronic Ignition General Troubleshooting Limited Lifetime Warranty Policy 41D2001 Rev 3 Dec