MAINTENANCE
TROUBLE SHOOTING REGENCY GAS SPACE HEATER
|
|
| SYMPTOM |
| PROBABLECAUSE | CORRECTIVEACTION |
|
|
|
|
|
|
|
|
|
| 1) | Thin black coating [soot]forms on view- | a) | Incorrect gas pressure | Check and correct gas pressure if sooting |
| |
|
|
| ing glass. | b) | Not enough combustion | continues open aeration shutter on burner. |
|
|
|
|
|
| air | Note: To clean glass, remove and wipe with |
|
|
|
|
|
|
| cloth or paper towel |
|
|
|
|
|
|
|
|
|
| 2) | A change in flame appearance or burn- | a) | A change in gas pressure | Check gas pressure. |
| |
|
|
| er operations | b) | Carbon dirt or lint | Clean out carbon, spider webs, lint etc. from |
|
|
|
|
|
|
| burner area. |
|
|
|
|
|
|
|
|
|
| 3) | No air flow | a) | Fan failure | Check and replace fan assembly |
| |
|
|
|
|
|
| Check and replace fan switch |
|
|
|
|
|
|
| Check and replace thermodisc |
|
|
|
|
|
|
|
|
|
| 4) | Burners will not light. | a) | Pilot flame out | Relight [follow lighting procedure completely] |
| |
|
|
|
| b) Control knob on pilot | Adjust pilot. |
| |
|
|
|
| c) | Low voltage from Thermopile. | Thermopile, check and replace if faulty |
|
|
|
|
|
| *280mil volts on pilot |
|
|
|
|
|
|
| *120mil volts when main burner is on |
|
|
|
|
|
|
|
|
| |
| 5) | Pilot goes out. | a) | Check thermocouple voltage | Replace thermocouple. |
| |
|
|
|
|
|
|
|
|
SERVICE SHOULD BE CARRIED OUT BY AUTHORIZED PERSONNEL ONLY
ABNORMALOPERATION
If main burner does not light but pilot stays on, shut down heater and contact your dealer. If excessive carbon on logs or glass contact your dealer for service.
THE MAJOR CAUSE OF
OPERATING PROBLEMS WITH GAS HEATERS IS IMPROPER GAS PRESSURE
Such problems as changes in flame col- our or configuration, burner outages, in- termittent operations, changes in heat output, excessive burner noise, are nearly always the result of changes in gas pres- sure or improper gas pressure at time of installation.
THE MOSTIMPORTANTITEMTO CHECK DURING THE INSTALLATION AND THE FIRST THING TO CHECK WHEN PROB- LEMS OCCUR IS GAS PRESSURE.
CHECK DATA PLATE FOR COR- RECT PRESSURE SETTINGS
INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COV- ERED BY WARRANTY, A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES