WARRANTY

Regency fireplace products are designed with reliability and simplicity in mind. In addition, our internal Quality Assur- ance Team carefully inspects each unit thoroughly before it leaves our door. Regency Industries Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product.

The Warranty: Lifetime

Covered under the agreement are the following components: Combustion chamber, heat exchanger, burner tubes, logs, embers,glass(thermalbreakage)andallgoldplating(against defective manufacture).

The above will be covered for parts and labour for the first five years and parts only thereafter.

Electrical components such as blowers, switches, wiring, thermodiscs, remote control, thermopiles, thermocouples and gas valves are covered for one year from the date of purchase.

Conditions:

All installations must be performed by an authorised gas fitter and installed according to all applicable local and national codes. Also, all service work must be carried out by an authorised gas service person. It is the responsibility of the installer to ensure that the appliance is firing as per rating plate. Any part or parts of this unit which in our judgement show evidence of such defect will be repaired or replaced at Regency's option, through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested. In areas where there is not an approved service agent or the closest approved service agent is situated more than twenty-five (25) kilometres from the installation, Australian Heating Distrib- utors are not obliged to arrange warranty repairs and travel and/or additional labour charges will apply.

Exclusions:

This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim. It does not cover installation and operational related problems such as over- firing, downdrafts or spillage caused by environmental con- ditions, nearby trees, buildings, hilltops, mountains, inade- quate flueing or ventilation, excessive offsets, negative air pressures caused by insufficient make up air, mechanical systems such as furnaces, fans, clothes dryers etc.

The warranty does not extend to any part or parts which show evidence of misuse or abuse, neglect, accident or lack of maintenance.

Products made by other manufacturers and used in conjunc- tion with the operation of this appliance without authorization from Regency, may nullify your warranty on this product.

Regency Industries Ltd., shall in no event be liable for any special, indirect consequential damages of any nature whatsoever which are in excess of the original purchase price of the product. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior facia is not the responsibility of Regency Industries Ltd.

General:

It is essential that all submitted claims provide all of the necessary information including purchase date, serial #, type of unit and part or parts requested.

DISTRIBUTORS:

Western Australia

Eastern Australia

 

AUSTRALIAN HEATING DISTRIBUTORS

FIREPLACE PRODUCTS AUSTRALIA PTY. LTD.

 

31 CLUNE STREET

21-23 SOUTH LINK BLVD.

 

BAYSWATER, WA 6053

DANDENONG, VIC 3175

SERVICE AGENTS:

HEARTH HOUSE SERVICE

 

 

 

 

31 CLUNE STREET

 

 

BAYSWATER, WA 6053

 

NOTE: PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION

INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY

A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES.

Regency I31-3 Gas Fireplace Inbuilt

27

Image 27
Contents Please Keep These Instructions For Future Reference ManualRegency GAS Fireplace Inbuilt Fireplace Table of Contents Data Badge Installation Minimum Fireplace Dimensions GAS ConnectionMinimum Clearances to Combustibles GAS Pressure Test DiagramDraft Diverter Connection FlueingLOG SET Installation Optional Brick PanelVermiculite Embers Per instructions in this manual Pins on Rear Log SupportPinCutout Notch CutoutFaceplate & Trim Installation Flush Front InstallationDiagram Rear View Trim Assembly Australia BAY Front InstallationBAY Louvres Flush LouvresHampton Cast Faceplate Installation Switch Box Assembly Boss on rear left side PieceEnsure that the top Sides are Aligned Grill Stop Bracket Hampton Cast Grill InstallationSide Hook Slots Regency Logo Left Hand Side FaceplateClose louver Barossa Curved Front InstallationOptional Remote Control WiringOptional Wall Thermostat Operating Instructions Gas Control Valve Maintenance InstructionsCopy of Lighting Instruction Plate Pilot FlameMaintenance LOG Replacement Door GlassGOLD-PLATED Trim Remove the 2 screws holding Grate in position FAN MaintenanceGlass Gasket Replacing fanSymptom Probablecause Correctiveaction Trouble Shooting Regency GAS Space HeaterParts List Main AssemblyDescription Burner Assembly & LOG SET Faceplate Assembly BAY & Flush Front Assembly Bay DoorFlush Door Hampton Cast Faceplate Assembly Regency I31-3 Gas Fireplace Inbuilt Western Australia Eastern Australia Warranty