INSTALLATION
The smoke should be drawn into the spill tube. If the smoke is still not drawn into the spill tube, turn the unit off and check for the cause of the lack of draft. If necessary, rectify.
For wind turbulent sites, a wind cap may rem- edy the problem.
Note: The thermally activated safety switch will sense the change in temper- ature and shut down the gas valve in the event of a severe downdraft or a blocked or disconnected flue. The switch acts as a safety
If the heater turns off because of lack of draft during the spillage test, check for the cause and if necessary, rectify.
The thermally actuated safety switch will automatically reset after it has cooled off. The switch will continue to cycle until the draft problem is corrected. DO NOT BY-
PASS OR DISCONNECT THIS SWITCH.
OPTIONAL
BRICK PANEL
1)Unwrap the brick pattern panels from the protective wrapping.
2)Remove the glass front if it is already installed (see manual).
3)Put the rear brick panel flat against the back of the unit.
4)Before installing the side brick panels, loos- en the screws for the brick tabs enough so that you can slide the brick tabs on to the screws easily but that the tabs are secure. For the location of the side brick tab screws see diagram 1.
Diagram 1
5)Remove the brick tabs and slide the side brick panels into position. See diagram 3. Install the brick tabs. See diagram 2.
Diagram 2
LOG SET
INSTALLATION
Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.
The gas log kit contains the following:
a) | Rear Log | ||
b) | Front Right Log | ||
c) | Middle Left Log | ||
d) | Left Top Log | ||
e ) | Center Log | ||
f) | Middle Right Log | ||
g) | Front Left Log |
h)Embers and Rockwool
i)Vermiculite and Ember combination
Note: Install Optional Brick Panels prior to installing logs.
The "02" refer numbers (i.e.
molded into the rear of each log.
1)Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position.
2)Sprinkle the vermiculite and ember combi- nation around the firebox base.
Vermiculite and |
| Vermiculite and |
embers. | Vermiculite and | embers. |
| embers. |
|
3)Place Rear Log
Diagram 3
8 | Regency |