Vanguard Managed Solutions BHDV34PB installation manual Vertical Venting

Page 14

®

BHDV34NB AND BHDV34PB

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

VENTING

INSTALLATION

Continued

Note: Install restrictor into 4" collar of fireplace as shown.

Note: Install restrictor into 4" collar of fireplace as shown.

RVF Kit Shown

Venting with Two 90° Elbows

Vertical (V1)

Horizontal (H)

5' min.

6' max.

6' min.

12' max.

7' min.

18' max.

8' min.

20' max.

Note: Vertical (V1) +

Vertical (V2) = 20' max.

Figure 27 - Vertical Rigid Venting Configuration Using Two 90° Elbows

Vertical Venting

V = 40' max.

Figure 28 - Vertical Rigid Venting Con- figuration With No Horizontal Run

14

106516

Image 14
Contents Natural GAS Model BHDV34NB PROPANE/LP GAS Model BHDV34PB For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Local Codes Product FeaturesProduct Identification Glossary TermsLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingGeneral Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Cathedral Ceiling Installation Installation for Vertical TerminationFlat Ceiling Installation Vertical Termination Configurations Venting with One 90 ElbowVertical Venting Venting Installing GA3700/DA3610TA Blowers Fireplace InstallationInstalling Optional Blower Accessory Check GAS TypeSide View Installing GAS Piping to Fireplace Location Installation Items NeededChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas Connections Close equipment shutoff valve see Fig- ureInstalling Optional Wall Mounted Thermostat GWMT1 Installing Optional Wall Mount Switch GWMS2REMOVING/REPLACING Glass Door Installing 9-Volt Alkaline Battery into ReceiverInstalling 9-Volt Battery in Hand- Held Remote Control Unit Installing Optional Brick Liner D8037A Installing Left Side Brick PanelInstalling LOGS, Lava Rock and Glowing Embers Shown in FigureOperating Fireplace Ghrcta Series Operation Operating Optional Blower AccessoryGhrc Series Operation Inspecting Burners Operating Optional GWMS2 Wall Mounted SwitchPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning and MaintenanceGlass Door Venting SystemTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Technical Service Replacement PartsWiring Diagram Service HintsSpecifications BHDV34NB BHDV34PBAccessories Brass Louver KIT Receiver and HAND-HELD Remote Control KIT Ghrc SeriesDuplex Outlet KIT Manual Blower KIT GA3700Illustrated Parts Breakdown BHDV34NB BHDV34PB33Parts List DIRECT-VENT Fireplace BHDV34NB BHDV34PBWarranty Information