Vanguard Managed Solutions BHDV34PB installation manual Pressure Testing Fireplace Gas Connections

Page 20

®

BHDV34NB AND BHDV34PB

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

FIREPLACE INSTALLATION

Continued

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Fig- ure 37).

2.Pressurize supply piping system by ei- ther opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace, or using compressed air.

3.Check all joints from propane/LP sup- ply tank or gas meter to equipment shutoff valve (see Figure 38 for pro- pane/LP or Figure 39 for natural). Ap- ply commercial leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Fireplace Gas Connections

OpenON

POSITION

Equipment

Shutoff

Valve

OFF

ClosedPOSITION

Figure 37 - Equipment Shutoff Valve

Propane/LP Supply

Tank

Equipment

Shutoff Valve

Gas Valve

Figure 38 - Checking Gas Joints for Propane/LP Gas Fireplace

1.Open equipment shutoff valve (see Fig- ure 37).

2.Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natu- ral gas fireplace.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (see Fig- ure 38 for propane/LP or Figure 39 for natural). Apply commercial leak test so- lution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

5.Light fireplace (see Operating Fire- place, pages 25 through 27). Check all other internal joints for leaks.

6.Turn off fireplace (see To Turn Off Gas to Appliance, page 25).

Equipment

Shutoff Valve

Gas Meter

Gas Valve

Figure 39 - Checking Gas Joints for Natural Gas Fireplace

20

106516

Image 20
Contents Natural GAS Model BHDV34NB PROPANE/LP GAS Model BHDV34PB For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Product Features Product IdentificationLocal Codes Glossary TermsPRE-INSTALLATION Preparation ClearancesLocation and Space Requirements Framing and FinishingGeneral Venting Location of Vent TerminationGeneral Venting Venting Installation Installation PrecautionsInstallation Planning Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Cathedral Ceiling Installation Installation for Vertical TerminationFlat Ceiling Installation Vertical Termination Configurations Venting with One 90 ElbowVertical Venting Venting Fireplace Installation Installing Optional Blower AccessoryInstalling GA3700/DA3610TA Blowers Check GAS TypeSide View Installing GAS Piping to Fireplace Location Installation Items NeededChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas Connections Close equipment shutoff valve see Fig- ureInstalling Optional Wall Mounted Thermostat GWMT1 Installing Optional Wall Mount Switch GWMS2REMOVING/REPLACING Glass Door Installing 9-Volt Alkaline Battery into ReceiverInstalling 9-Volt Battery in Hand- Held Remote Control Unit Installing Optional Brick Liner D8037A Installing Left Side Brick PanelInstalling LOGS, Lava Rock and Glowing Embers Shown in FigureOperating Fireplace Ghrcta Series Operation Operating Optional Blower AccessoryGhrc Series Operation Operating Optional GWMS2 Wall Mounted Switch Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatCleaning and Maintenance Glass DoorPilot and Burners Venting SystemTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Replacement Parts Wiring DiagramTechnical Service Service HintsSpecifications BHDV34NB BHDV34PBAccessories Receiver and HAND-HELD Remote Control KIT Ghrc Series Duplex Outlet KITBrass Louver KIT Manual Blower KIT GA3700Illustrated Parts Breakdown BHDV34NB BHDV34PB33Parts List DIRECT-VENT Fireplace BHDV34NB BHDV34PBWarranty Information