Vanguard Managed Solutions BHDV34PB Installing Optional Wall Mounted Thermostat GWMT1

Page 21

OWNER’S MANUAL

FIREPLACE INSTALLATION

Continued

INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1

WARNING: Installation must be done by a qualified installer familiar with low voltage wiring procedures.

WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.

NOTICE: The GWMT1 includes 25' of wire for installation. Your fire- place includes 15' of wire for ac- cessory installation. Choose the length that best fits your needs when installing this accessory.

1.Open lower louver panel. The valve is attached to the underside of the firebox assembly.

2.Disconnect the wire that runs from TH to TPTH from the valve as shown in Figure 40.

3.Connect one terminal of the provided wire for the wall thermostat to the TPTH terminal on the valve. Connect remaining wire terminal to the TH ter- minal on the valve. Make sure that the wire terminals are in the positions on the unit as pictured in Figure 41. If wires are not connected as shown the thermostat will not work.

4.Route the wire through openings pro- vided on the sides of the fireplace to a convenient location to mount your ther- mostat (no outside wall).

IMPORTANT: The wire may be short- ened but must not be lengthened.

The thermostat should be mounted 54" above the floor in a location where there is good air circulation. Avoid heat sources such as lamps, direct sunlight, fireplace, or heat and air conditioning ducts.

5.Gently remove the cover of the ther- mostat from the base. Grasp the sides of the cover firmly and pull to separate from the base.

6.Feed the electrical wires through the rectangular slots (from the back) on each side of the base (see Figure 42).

WARNING: Do not connect this thermostat to a power source. Electrical shock and/or fire haz- ard will occur.

7.Connect one bare wire end to each ter- minal (“W” and “R”) of the thermostat base (see Figure 43).

8.Install the base to the wall with screws provided with thermostat.

9.Move the temperature adjustment back and forth to insure the bimetal is free from restrictions.

10.Replace the cover onto the base. (Upon installation, the thermostat must be al- lowed to stabilize at room temperature for a minimum of 30 minutes for proper operation.)

11.Set the temperature adjustment to the desired setting.

This thermostat has been electronically calibrated at the factory. No adjustment or leveling is necessary.

To Wall Optional

Remote Accessory

t

Feed wires through rectangular slots

Figure 42 - Back View of Thermostat Base

 

Terminal “W”

W

R

Terminal “R”

Figure 43 - Thermostat Base Terminals “W” and “R”

INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2

NOTICE: The GWMS2 includes 25' of wire for installation. Your fireplace includes 15' of wire for accessory installation. Choose the length that best fits your needs when installing this accessory.

1. Connect one terminal of the provided

wire for the wall switch to the TPTH ter-

minal on the valve. Connect remaining

wire terminal to the TH terminal on the

valve. Make sure that the wire terminals

are in the positions on the unit as pic-

tured in Figure 41. If wires are not con-

nected as shown the switch will not work.

2. Route the wire through openings pro-

vided on the sides of the fireplace to a

Figure 41 - Control Valve Terminals

Figure 40 - Disconnecting TH to TPTH

Wire

 

convenient location to mount your switch.

3.

Connect one bare wire end to each of the

 

terminals of the GWMS2 wall switch.

4.

Install the wall switch and cover in the

 

wall.

Continued

106516

21

Image 21
Contents For Your Safety For Your Safety What to do if YOU Smell GASNatural GAS Model BHDV34NB PROPANE/LP GAS Model BHDV34PB Safety Information Product Identification Product FeaturesLocal Codes Glossary TermsClearances PRE-INSTALLATION PreparationLocation and Space Requirements Framing and FinishingLocation of Vent Termination General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Venting Installing Optional Blower Accessory Fireplace InstallationInstalling GA3700/DA3610TA Blowers Check GAS TypeSide View Installation Items Needed Installing GAS Piping to Fireplace LocationConnecting Fireplace to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Close equipment shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsInstalling Optional Wall Mount Switch GWMS2 Installing Optional Wall Mounted Thermostat GWMT1Installing 9-Volt Alkaline Battery into Receiver Installing 9-Volt Battery in Hand- Held Remote Control UnitREMOVING/REPLACING Glass Door Installing Left Side Brick Panel Installing Optional Brick Liner D8037AShown in Figure Installing LOGS, Lava Rock and Glowing EmbersOperating Fireplace Operating Optional Blower Accessory Ghrc Series OperationGhrcta Series Operation Pilot Assembly Operating Optional GWMS2 Wall Mounted SwitchInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners Venting SystemObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Replacement PartsTechnical Service Service HintsBHDV34NB BHDV34PB SpecificationsAccessories Duplex Outlet KIT Receiver and HAND-HELD Remote Control KIT Ghrc SeriesBrass Louver KIT Manual Blower KIT GA3700BHDV34NB BHDV34PB33 Illustrated Parts BreakdownDIRECT-VENT Fireplace BHDV34NB BHDV34PB Parts ListWarranty Information