BHDV34NB AND BHDV34PB
OPERATING
FIREPLACE
Continued
1. After lighting, let pilot flame burn for |
about one minute. Turn gas control |
knob on the control valve to ON posi- |
tion. Turn variable control knob any- |
where between WARMER and |
COOLER. Slide the selector switch to |
the REMOTE position. Note: The |
burners may light if |
ON button was on when selector switch |
was last turned off. You can now turn |
the burners on and off with either op- |
tional |
IMPORTANT: Do not leave the se- |
lector switch in the REMOTE posi- |
tion when the pilot is not lit. This will |
drain the battery. |
IMPORTANT: This remote control has been specially engineered to take an air temperature sample every 5.5 minutes in the auto mode. It will not respond immediately to the tempera- ture setting being turned up or down.
IMPORTANT: The
3.To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit.
IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position.
OPERATING
OPTIONAL BLOWER
ACCESSORY
Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel.
Both the GA3700 manual blower and the DA3610TA
Note for DA3610TA Only: If you are using DA3610TA blower with optional thermostat (wall mount or remote con- trol) for the fireplace, your fireplace and blower will not turn on and off at the
IMPORTANT: Be sure to press the |
ON/OFF buttons on the |
remote control unit for up to 3 sec- |
onds to assure proper operation. |
GHRC Series Operation:
2a. Press the ON/OFF button to turn the burners on and off. When turning burners off, the pilot will remain lit.
GHRCTA Series Operation:
Blower Control Knob (Optional Accessory)
OFF
ON
REMOTE
OFF
ON
Selector Switch in Remote Position
Variable Control Knob
N |
| L |
|
O |
| O | I |
T | F | O | H |
O |
|
| |
F |
|
| |
LIP |
|
|
|
|
|
|
|
Gas Control
Knob in On
Position
same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.
The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air.
2b. Press the AUTO/ON/OFF button on the
•In the ON mode, the burners will ignite. The heater is in manual mode when ON is lit.
•In the AUTO mode, the thermostat in the
Figure 57 - Setting the Selector Switch, Gas Control Knob, and Variable Control Knob for Remote Operation
| Increases Room | |
Shows Tempera- | Temperature in | |
AUTO Mode | ||
ture Setting | ||
| ||
| Decreases Room | |
The Log Heater | Temperature in | |
AUTO Mode | ||
will Automatically | ||
| ||
Cycle between | Turns Burners | |
Pilot and the Heat | ||
On or Off and | ||
Setting that has | ||
Allows You to | ||
been Selected | ||
Choose the Auto | ||
| ||
| Setting |
Figure 58 - Hand-Held Thermostat Remote Control Unit Selections (GHRCTA Only)
26 | 106516 |