FIREPLACE INSTALLATION

Continued

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

5/16" hex socket wrench or nut-driver

sealant (resistant to propane/LP gas, not provided)

1.Open lower louver door panel by gen- tly pulling forward.

2.Route flexible gas line (provided by installer) from equipment shutoff valve to fireplace. Route flexible gas supply line through one of the access holes on side of fireplace.

3.Attach flexible gas line from gas sup- ply to control valve (see Figure 36).

4.Check all gas connections for leaks. See Checking Gas Connections.

CHECKING GAS

CONNECTIONS

WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply commercial leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect appliance with its appli- ance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will dam- age heater regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by ei- ther opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace, or using compressed air.

4.Check all joints of gas supply piping system. Apply commercial leak test solution to all gas joints. Bubbles form- ing show a leak. Correct all leaks at once.

5.Reconnect fireplace and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.

To Gas Supply (Natural)

Equipment Shutoff Valve

To External Regulator (Propane/LP)

Control Valve

Flexible Gas Line from

Equipment Shutoff Valve

Provided by Installer

Figure 36 - Attaching Flexible Gas Line To Control Valve

Continued

106516

19

Image 19
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyNatural GAS Model BHDV34NB PROPANE/LP GAS Model BHDV34PB Safety Information Glossary Terms Product FeaturesProduct Identification Local CodesFraming and Finishing PRE-INSTALLATION PreparationClearances Location and Space RequirementsLocation of Vent Termination General VentingGeneral Venting Installing Vent System in a Chase Venting InstallationInstallation Precautions Installation PlanningSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Venting Check GAS Type Fireplace InstallationInstalling Optional Blower Accessory Installing GA3700/DA3610TA BlowersSide View Installation Items Needed Installing GAS Piping to Fireplace LocationPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyChecking GAS Connections Close equipment shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsInstalling Optional Wall Mount Switch GWMS2 Installing Optional Wall Mounted Thermostat GWMT1Installing 9-Volt Battery in Hand- Held Remote Control Unit Installing 9-Volt Alkaline Battery into ReceiverREMOVING/REPLACING Glass Door Installing Left Side Brick Panel Installing Optional Brick Liner D8037AShown in Figure Installing LOGS, Lava Rock and Glowing EmbersOperating Fireplace Ghrc Series Operation Operating Optional Blower AccessoryGhrcta Series Operation Operating Optional GWMT1 Wall Mounted Thermostat Operating Optional GWMS2 Wall Mounted SwitchPilot Assembly Inspecting BurnersVenting System Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Service Hints Replacement PartsWiring Diagram Technical ServiceBHDV34NB BHDV34PB SpecificationsAccessories Manual Blower KIT GA3700 Receiver and HAND-HELD Remote Control KIT Ghrc SeriesDuplex Outlet KIT Brass Louver KITBHDV34NB BHDV34PB33 Illustrated Parts BreakdownDIRECT-VENT Fireplace BHDV34NB BHDV34PB Parts ListWarranty Information