Venting Installation instructions
Continued
HORIZONTAL SYSTEM INSTALLATION USING TWO 90° ELBOWS
The following configurations show the minimum vertical rise requirements for a horizontal system using two 90° elbows.
Venting with Two 90° Elbows
|
| Horizontal (H1) + |
Vertical (V) | Horizontal (H1) | Horizontal (H2) |
5' min. | 2' max. | 6' max. |
6' min. | 4' max. | 12' max. |
7' min. | 6' max. | 18' max. |
8' min. | 8' max. | 20' max. |
20' max. | 8' max. | 20' max. |
45° Elbow
Figure 17 - Horizontal Termination Configuration for Venting Using Two 90° Elbows
Venting with Two 90° Elbows |
| ||
| Horizontal (H1) + |
| |
Vertical (V) Horizontal (H2) |
| ||
5' min. | 6' max. |
| |
6' min. | 12' max. |
| |
7' min. | 18' max. | 45° Elbow | |
8' min. | 20' max. | ||
| |||
20' max. | 20' max. |
|
Figure 18 - Horizontal Termination Configuration for Venting Using Two 90° Elbows
with Termination at 90° with Fireplace