Desa (V)T32EP-A SERIES, (V)T32EN-A SERIES Blower Model BKT, Blower Wiring Diagram

Page 19

Fireplace

Installation

Continued

3.Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward and the thermodisc positioned up near the fireplace bottom. The thermodisc must be oriented near the fireplace bottom as shown in Figure 28, in order to sense tempera- ture and properly operate. The blower will be held in position against the back wall by the magnets incorporated onto the blower housing (see Figure 28).

4.Be certain that all wire terminals are securely at- tached to terminals on blower motor and thermal switch and that the screw for the thermodisc bracket and green ground wire is tight.

5.Mount the speed control box against the mounting plate provided in the lower fireplace cavity by placing the plastic control shaft forward through the round hole (see Figure 26, page 18).

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against mounting plate. Place control knob provided on shaft (see Figure 26, page 18).

7.Check to make sure that the power cord is com- pletely clear of the blower wheel and that there are no other foreign objects in blower wheel. Also double check all wire leads and make sure wire routing is not pinched or in a precarious position. Correct accordingly.

8.Turn on power to duplex outlet if previ- ously turned off per the warning in column 2, page 17.

9.Plug in blower power cord to duplex outlet.

10.The blower will only run when the speed control knob is in the ON position and the thermal switch senses temperature after the fireplace begins to heat up. The blower speed can be adjusted by rotating the control knob. To turn off, turn knob fully counterclockwise until it clicks off. If the blower is ON and has been running with the fireplace operating, the blower will continue to run for a short time after the fireplace has been turned off. As the thermal switch cools down, the blower shuts down automatically.

11.Peel off the backing paper and stick the sup- plied wiring diagram decal on the firebox bot- tom approximately 12" in front of the blower (see Figure 27, page 18).

Power

White Wire

Blue Wire

Cord

 

Magnetic

Black

 

Strips

 

Air Flow

Wire

 

Direction

Thermal

Thermal

Ring

Switch

Switch

Bracket

Phillips

Terminal

 

Screw

on Green

Route BKT Blower

Wire

Air Flow

 

 

Direction

Through This Area

 

 

 

Thermodisc

Side View Firebox Bottom

Blower

Location

Magnets

Figure 28 - Blower Model BKT

Blower Wiring Diagram

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dan- gerous operation. Verify proper operation after servicing.

 

 

 

Variable

Fan Switch

 

 

Fan Switch

 

 

 

 

(N.O.)

 

 

Off

1

Black

 

 

 

2

110/115

On

 

Blue

 

 

 

V.A.C. Black

 

Blower

 

 

 

 

 

 

White

 

Motor

Green

Figure 29 - Blower Wiring Diagram for

Thermostat-Controlled Models

116647-01B

www.desatech.com

19

Image 19
Contents What to do if YOU Smell GAS Safety Information Table of ContentsSafety Information Product Identification Product FeaturesLocal Codes Flush with a wall Pre-Installation PreparationLocation and space requirements ClearancesFraming and finishing Termination CAP AIR Supply Inlet GAS Meter Location of Termination CapInstallation Precautions Venting Installation InstructionsHole Installation PlanningMale Slots Female Locking Lugs CenterNoncombustible Exterior Vent Cap Wood ScrewSquare Termination Venting InstallationHorizontal H 65 3/4 min Wall Firestop Elbow43 3/4 min None 53 3/4 minMin Max 12 max 18 max Elbow 20 max Venting with Two 90 ElbowsMin Max 12 max 18 max 20 max Elbow Vertical V Horizontal HIf area above is a Installation for vertical terminationFlat Ceiling Installation Roof Flashing Wall Strap Elbow Ceiling FirestopVenting with One 90 Elbow Vertical V Horizontal H Min Max 20 max ElbowMin Max 12 max 18 max 20 max = 40 max Elbow High Altitude InstallationParts list for venting kits and components Vertical VentingCheck GAS Type Fireplace InstallationInstalling optional blower accessory Model BK InstallationModel BKT Installation Wiring Diagram Decal 12 in Front BlowerRight outside Blower Model BKT Blower Wiring DiagramInstallation Items Needed Installing Gas Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyRed Surface Removing Louver Panels Pressure Testing Fireplace Gas ConnectionsRemoving/Replacing Glass Door Test Pressures Equal To or Less Than Psig 3.5 kPaCleaning Glass Door Installing Optional Brick liner Model BL32DRemoving Glass Door Left Side Brick Panel Installing logs, lava rock and glowing embersOptional Remote control Installation model WRC Wall Switch InstallationLighting Instructions Wiring DiagramFor Your Safety Read Before Lighting Operating FireplaceTo Turn OFF GAS To Appliance Operating optional blower accessoryOptional Remote Operation Burner Flame Pattern Cleaning MaintenancePilot Assembly Inspecting BurnersLogs Pilot and burnersVenting system Observed Problem Possible Cause Remedy TroubleshootingChecking Gas Connections Gas leak. See WarningSpecifications Replacement PartsService Hints Technical ServiceRemote Control KIT WRC AccessoriesIllustrated Parts Breakdown 22-2 1141814123 21171 24353 24460 22-1109 Electronic Valve Propane/LP 116647-01B 116647-01B Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace