Desa (V)T32EP-A SERIES, (V)T32EN-A SERIES Fireplace Installation, Check GAS Type

Page 17

Venting Installation

instructions

Continued

Number

Description

 

HHTK-58

High Wind Round Horizontal

 

Termination Kit (Includes Round

 

Termination,

Wall Firestop,

 

45° Elbow)

 

HHT-58

High Wind Round Termination Kit,

 

Galvinized

 

HTK-58

Horizontal Round Termination Kit

 

(Includes Round Termination,

 

Wall Firestop, 45° Elbow)

HT-58

Horizontal Round Termination,

 

Galvanized

 

HTS-58

Horizontal Square Termination,

 

Galvanized

 

HTKS-58

Horizontal Square Termination Kit

 

(Includes: Square Termination,

 

Wall Firestop, 45° Elbow)

HTS-58

Horizontal Square Termination,

 

Galvanized

 

VT-58

Vertical Round Termination,

 

Galvanized

 

ST-58-14

14" Snorkel

Termination,

 

Galvanized

 

ST-58-36

36" Snorkel

Termination,

 

Galvanized

 

SC-58

Storm Collar, Galvanized

WF-58

Wall Firestop, Galvanized

RF-58-6

Roof Flashing - 0 to 6/12 Pitch,

 

Galvanized

 

RF-58-12

Roof Flashing - 6/12 to 12/12

 

Pitch, Galvanized

VR-58

Vertical Restrictor, Galvanized

S-58

V i n y l S i d i n g S t a n d o f f ,

 

Galvanized

 

WS-58

Wall Strap

 

CS-58

Cathedral Ceiling Support

FP-58

Firestop Plate

 

SF-58

Stucco Flashing - For use

 

with HTS-58

 

RF-58

Flat Roof Flashing

Fireplace

Installation

CHECK GAS TYPE

Use proper gas type for the fireplace unit you are installing. If your gas supply is not correct, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gas type or to purchase gas conversion kit (see Ac- cessories, page 33).

Installing optional blower accessory

NOTICE: If installing blower in an existing fireplace with gas connections, shut off gas sup- ply and disconnect heater from gas supply. Contact a qualified service person to do this.

WARNING: If there is a duplex electrical outlet installed in the right side of the bottom of the fireplace base area, be sure that theelectricalpowertotheoutletis turned off before proceeding with blower installation. Failure to do this may result in serious injury.

Model BK Installation

Follow all instructions provided in the blower accessory kit.

1.Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor (see Figure 25).

2.Attach green ground wire from power cord to blower housing using screw provided (see Figure 25). Tighten screws securely.

Side View

Blower

Lower Firebox

Location

Magnetic

Cavity

Strips

Spade

 

Terminals

 

Green

 

Ground

 

Wire

 

Screw Exhaust

Port

Figure 25 - Blower Model BK

116647-01B

www.desatech.com

17

Image 17
Contents What to do if YOU Smell GAS Safety Information Table of ContentsSafety Information Local Codes Product FeaturesProduct Identification Location and space requirements Pre-Installation PreparationClearances Flush with a wallFraming and finishing Termination CAP AIR Supply Inlet GAS Meter Location of Termination CapInstallation Precautions Venting Installation InstructionsMale Slots Female Locking Lugs Installation PlanningCenter HoleNoncombustible Exterior Vent Cap Wood ScrewHorizontal H Venting InstallationSquare Termination 43 3/4 min None Wall Firestop Elbow53 3/4 min 65 3/4 minMin Max 12 max 18 max 20 max Elbow Venting with Two 90 ElbowsVertical V Horizontal H Min Max 12 max 18 max Elbow 20 maxFlat Ceiling Installation Installation for vertical terminationRoof Flashing Wall Strap Elbow Ceiling Firestop If area above is aMin Max 12 max 18 max 20 max Min Max 20 max ElbowVenting with One 90 Elbow Vertical V Horizontal H Parts list for venting kits and components High Altitude InstallationVertical Venting = 40 max ElbowInstalling optional blower accessory Fireplace InstallationModel BK Installation Check GAS TypeRight outside Wiring Diagram Decal 12 in Front BlowerModel BKT Installation Blower Model BKT Blower Wiring DiagramInstallation Items Needed Installing Gas Piping to Fireplace LocationRed Surface Connecting Fireplace to GAS SupplyChecking GAS Connections Removing/Replacing Glass Door Pressure Testing Fireplace Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Removing Louver PanelsRemoving Glass Door Installing Optional Brick liner Model BL32DCleaning Glass Door Left Side Brick Panel Installing logs, lava rock and glowing embersOptional Remote control Installation model WRC Wall Switch InstallationFor Your Safety Read Before Lighting Wiring DiagramOperating Fireplace Lighting InstructionsOptional Remote Operation Operating optional blower accessoryTo Turn OFF GAS To Appliance Pilot Assembly Cleaning MaintenanceInspecting Burners Burner Flame PatternVenting system Pilot and burnersLogs Observed Problem Possible Cause Remedy TroubleshootingChecking Gas Connections Gas leak. See WarningService Hints Replacement PartsTechnical Service SpecificationsRemote Control KIT WRC AccessoriesIllustrated Parts Breakdown 14123 21171 24353 24460 1141822-1 22-2109 Electronic Valve Propane/LP 116647-01B 116647-01B Limited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty