Desa BDV34N(A) installation manual REMOVING/REPLACING Glass Door, Installing Remote Receiver

Page 21

OWNER’S MANUAL

FIREPLACE INSTALLATION

Continued

INSTALLING OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL ACCESSORY - GHRC

Installing Remote Receiver

1.Open bottom louver and locate the switch bracket on the left.

2.Unscrew the switch bracket. Lean bracket forward so you are able to ac- cess the back of the remote receiver.

3.Locate the battery clip mounted on the back of the receiver. Slide a 9-volt bat- tery (not included) through the clip.

4.Attach the terminal wires to the battery.

5.Remove the wire that runs from TH to TPTH from the valve (see Figure 40).

6.Connect wires from reciever to TH and TPTH on the valve (see Figure 41).

7.Replace the switch bracket.

Figure 40 - Disconnecting TH to TPTH Wire

To Wall Optional

Remote Accessory

t

Figure 41 - Control Valve Terminals

Receiver

Terminal

Wires

Battery Clip

9-Volt Battery

Figure 42 - Attaching Battery to Receiver

Installing 9-Volt Battery in Hand- Held Remote Control Unit

1.Remove battery cover on back of re- mote control unit.

2.Attach terminal wires to a 9-volt bat- tery (not included). Place battery into the battery housing.

3.Replace battery cover onto remote con- trol unit.

 

Battery

 

Terminal

Cover

Remote

 

Wires

 

Control Unit

9-Volt

 

 

Battery

 

 

 

 

Battery

 

 

Housing

Figure 43 - Installing Battery in Hand- Held Remote Control Unit

REMOVING/REPLACING GLASS DOOR

You must remove glass door to install op- tional brick liners, logs, lava rock, and em- ber material.

CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For re- placement part information see Replacement Parts, page 30.

1.Remove the upper louver panel by lift- ing upward and out (see Figure 44).

2.Remove the screws from the three tabs at the top of the glass door while hold- ing door securely keeping it from fall- ing forward.

3.Grasp door by both sides and ease it upward off of the lower bracket (see Figure 45).

4.To replace glass door, follow the above instructions in reverse.

Top Louver

Panel

Figure 44 - Removing Top Louver Panel

Screw

Glass Door

Assembly

Lower Bracket for

Glass Door Assembly

Figure45 -Removing/ReplacingGlassDoor

Continued

105453

21

Image 21
Contents For Your Safety For Your Safety What to do if YOU Smell GASBDV34NA and BDV34PA DIRECT-VENT Fireplace NATURAL/PROPANE Safety InformationProduct Identification Product FeaturesLocal Codes Glossary TermsClearances PRE-INSTALLATION PreparationLocation and Space Requirements Framing and FinishingLocation of Vent Termination General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Vertical Rigid Venting Configuration Using Two 90 ElbowsParts Lists for Venting Kits and Components High Altitude InstallationVanguard Rigid Venting Vanguard Flexible VentingInstalling Optional Blower Accessory Fireplace InstallationInstalling GA3700/DA3610T Blowers Check GAS TypeSide View As a freestanding unit with an ac Installation Items Needed Installing GAS Piping to Fireplace LocationPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaInstalling Optional Wall Mount Switch GWMS2 Pressure Testing Fireplace Gas ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Installing Remote Receiver Installing 9-Volt Battery in Hand- Held Remote Control UnitREMOVING/REPLACING Glass Door Installing Left Side Brick Panel Installing Optional Brick Liner D8037Fireplace Models BDV34NA and BDV34PA Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsPilot Assembly Operating Optional Blower AccessoryInspecting Burners Optional Remote OperationCleaning and Maintenance Observed Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementTechnical Service Replacement Wiring Diagram PartsService Hints Parts Under WarrantyBDV34NA BDV34PA SpecificationsAccessories ON/OFF Wall Mount Switch GWMS2 Receiver and HAND-HELD Remote Control KIT Ghrc SeriesDuplex Outlet KIT GA3555 not Shown Brass Louver KITIllustrated PARTS37 Breakdown DIRECT-VENT Fireplace BDV34NA Parts ListBDV34PA7 DIRECT-VENT Fireplace BDV34PA Warranty Information