SPECIFICATIONS

 

BDV34N(A)

BDV34P(A)

 

 

 

 

15,000/21,000 Btu/hr

16,000/20,000 Btu/hr

 

 

 

Gas Type

Natural

Propane

 

 

 

Ignition

Piezo

Piezo

 

 

 

Manifold Pressure

3.5" w.c.

10.0" w.c.

 

 

 

Minimum Inlet Supply Pressure

4.5" w.c.

11.0" w.c.

 

 

 

Dimension, Inches/mm (HxWxD)

 

 

Fireplace

33" x 34" x 18 1/2"

33" x 34" x 18 1/2"

 

838 x 940 x 470mm

838 x 940 x 470mm

Carton

37" x 40" x 21"

37" x 40" x 21"

 

940 x 1016 x 533mm

940 x 1016 x 533mm

 

 

 

Weight, lbs/kg

 

 

Fireplace

132 lbs/60 kg

132 lbs/60 kg

Shipping

135 lbs/61 kg

135 lbs/61 kg

 

 

 

105453

31

Image 31
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyBDV34NA and BDV34PA DIRECT-VENT Fireplace NATURAL/PROPANE Safety InformationGlossary Terms Product FeaturesProduct Identification Local CodesFraming and Finishing PRE-INSTALLATION PreparationClearances Location and Space RequirementsLocation of Vent Termination General VentingGeneral Venting Installing Vent System in a Chase Venting InstallationInstallation Precautions Installation PlanningSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Vertical Rigid Venting Configuration Using Two 90 ElbowsVanguard Flexible Venting High Altitude InstallationParts Lists for Venting Kits and Components Vanguard Rigid VentingCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessory Installing GA3700/DA3610T BlowersSide View As a freestanding unit with an acInstallation Items Needed Installing GAS Piping to Fireplace LocationTest Pressures In Excess Of 1/2 Psig 3.5 kPa Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Installing 9-Volt Battery in Hand- Held Remote Control Unit Installing Remote ReceiverREMOVING/REPLACING Glass Door Installing Left Side Brick Panel Installing Optional Brick Liner D8037Fireplace Models BDV34NA and BDV34PA Installing LOGS, Lava Rock and Glowing EmbersLighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceOptional Remote Operation Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersCleaning and Maintenance Observed Problem Possible Cause Troubleshooting Observed Problem Possible Cause Remedy Above Gas leak. See Warning statementParts Under Warranty Replacement Wiring Diagram PartsTechnical Service Service HintsBDV34NA BDV34PA SpecificationsAccessories Brass Louver KIT Receiver and HAND-HELD Remote Control KIT Ghrc SeriesON/OFF Wall Mount Switch GWMS2 Duplex Outlet KIT GA3555 not ShownIllustrated PARTS37 Breakdown DIRECT-VENT Fireplace BDV34NA Parts ListBDV34PA7 DIRECT-VENT Fireplace BDV34PA Warranty Information