OWNER’S MANUAL
OPERATING
FIREPLACE
Continued
OPTIONAL REMOTE
OPERATION
Note: The GHRC receiver and hand- held remote control accessory must be purchased separately (See Accessories on page 33). Follow instructions included with the remote control.
NOTICE: You must light the pilot before using the
1. After lighting, let pilot flame burn for |
about one minute. Turn control knob |
on the control valve to ON position. |
Turn flame adjustment knob any- |
where between HI and LO. Turn the |
knob to the REMOTE setting. Note: |
The burner may light if |
mote ON button was on when selector |
switch was last turned off. You can now |
turn the burners on and off with the |
IMPORTANT: Do not leave the se- |
lector switch in the REMOTE posi- |
OPERATING
OPTIONAL BLOWER
ACCESSORY
Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel.
Both the GA3700 manual blower and the DA3610T thermostatically controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.
Note for DA3610T Only: Your fireplace and blower will not turn on and off at the same time. The fireplace may run for sev- eral minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.
The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air.
Blower Control Knob Flame
INSPECTING
BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary.
The height of the thermopile must be 3/8" to 1/2" above the pilot flame as shown in Figure
55.The thermocouple must be at a height of about 1/8" above the pilot flame. The flame from the pilot burner must extend beyond both the thermocouple and thermopile.
If your pilot assembly does not meet these requirements:
•turn fireplace off (seeTo Turn Off Gas to Appliance, page 24)
•seeTroubleshooting, pages 27 through 29
Thermopile
3/8" to 1/2"
Pilot Burner
tion when the pilot is not lit. This will |
drain the battery. |
IMPORTANT: Be sure to press the |
ON/OFF button on the |
mote control unit for up to 3 seconds |
to assure proper operation. |
(Optional Accessory)
OFF
ON
REMOTE OFF ON
Adjustment
Knob
N |
| L |
|
O |
| O | I |
T | F | O | H |
O | F |
|
|
LIP |
|
|
|
|
|
|
|
1/8"
Thermocouple
2. Press the ON/OFF button to turn the |
burners on and off. When turning |
burners off, the pilot will remain lit. |
IMPORTANT: To turn the pilot off, |
manually turn the control knob on |
the heater to the OFF position. |
Control Knob
Remote Control Knob in in On Position
Remote Position (Optional
Remote Control)
Figure 54 - Setting the Remote Control Knob, Valve Control Knob, and Flame Adjustment Knob for Remote Operation
Piezo
Ignitor
Figure 55 - Pilot Assembly
Continued