Desa LMFP33NR To Turn OFF GAS To Appliance, Manual Lighting Procedure, Shutting Off Heater

Page 18

18

OPERATING FIREPLACE

Lighting Instructions (Cont.)

To Turn Off Gas To Appliance

Manual Lighting Procedure

OPERATING HEATER

Continued

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the highest heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

WARNING: Burners will come on automatically within one minute when the control valve is in the ON position after the pilot is lit.

1.STOP! Read the safety information, page 17 column 2.

2.Make sure equipment shutoff valve is fully open.

3.Set remote selector switch in the AUTO position (see Figure 34).

4.Press in and turn control knob clockwise to the OFF position (see Figure 34).

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, page 17 column 2. If you don’t smell gas, go to the next step.

6.Press in and turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 34).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

7.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the rear of the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

Ignitor Button

Control Knob

Remote Selector Switch

AUTO MAN

 

Figure 34 - Remote Selector Switch, Control Knob and Ignitor Button

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8.

9.Slightly push in and turn control knob counterclockwise to the ON position.

10.Press the on/off key on the remote control to turn on appli- ance main burner. Wait at least 5 seconds before setting desired flame height.

11.Press the up or down key until the small triangle is to the left of large flame icon at the top of LCD display (see Fig- ure 37, page 19). Press the left or right key to set the de- sired flame height.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Pilot Burner

Ignitor

Pilot Burner

Ignitor

Electrode

 

Electrode

 

 

Figure 35 - Pilot (Propane/LP) Figure 36 - Pilot (Natural)

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Press on/off key on remote control and turn control knob

clockwise to the OFF position (see Figure 34).

Shutting Off Burners Only (pilot stays lit)

Press the on/off key on remote control or turn control knob

clockwise to the PILOT position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 7 under Lighting Instructions, column 1.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11 under Lighting Instructions above.

For..com

111604-01A

Image 18
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationLog Base Assembly Product IdentificationUnpacking Product FeaturesLocal Codes AIR for Combustion and VentilationUnusually Tight Construction Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationInstalling Hood Electrical HookupInstallation Clearances Included with Mantel AccessoryAssembling and Attaching Optional Brass Trim Conventional Fireplace Installation Installing Cabinet MantelBUILT-IN Fireplace Installation Actual Framing Height 32 3 Front Width DepthSupport Bracket Firebox Wrapper Shield Power Screws Cord Installing GAS Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Connecting Fireplace to GAS Supply Gas ConnectionPressure Testing gas Supply Piping system Checking GAS Connections Pressure Testing Fireplace Gas Connections Check all other internal joints for leaksInstalling Logs Installing Logs 1Installing Battery into Remote For Your Safety Read Before LightingInstalling Batteries in Receiver Operating HeaterShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off Burners Only pilot stays litHAND-HELD Remote Operation Burner Primary AIR Holes Inspecting BurnersPilot Flame Pattern Main BurnerCleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement Technical Service Wiring DiagramSpecifications Service HintsIllustrated Parts Breakdown Models LMFP33PRParts List KEY Part Number LMFP33PR LMFP33NR Description QTYFirebox LMFP33PR LMFP33NR Firebox LMFP33PR and LMFP33NR KEY Part Number Description QTYEquipment Shutoff Valve GA5010 AccessoriesBlower Accessory GA3750A GA3700TA Series Information VideoOwners Registration Form Postage Required 111604-01A Warranty Information