Desa LMFP33NR installation manual Gas leak. See Warning statement

Page 24

24

TROUBLESHOOTING

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Fireplace produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most heaters. If noise is excessive, contact qualified ser- vice person

Fireplace produces unwanted odors

1.

Heater burning vapors from paint, hair

 

 

spray, glues, cleaners, chemicals, new

 

 

carpet, etc. (See IMPORTANT state-

 

 

ment above)

 

2.

Low fuel supply (propane/LP only)

 

3.

Gas leak. See Warning statement

 

 

at top of page

1.Open window to ventilate room. Stop us- ing odor causing products while heater is running

2.Refill supply tank (propane/LP only)

3.Locate and correct all leaks (see Check- ing Gas Connections, page 14)

Fireplace shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local natural or propane/LP gas

 

 

 

 

company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 21)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see Check-

position

 

at top of page

 

ing Gas Connections, page 14)

 

2.

Control valve or gas control defective

2.

Replace control valve or gas control

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement

 

 

at top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Check- ing Gas Connections, page 14)

Dark residue on logs inside of their fireplace

1.

Improper log placement

1.

Properly locate logs (see Installing Logs,

Note: After removing all causes of residue

 

 

 

page 16)

deposits, completely clean fireplace and ap-

2.

Drafts or other air currents affecting

2.

Eliminate source of drafts around heater

pliance off residue before reusing appliance

 

flame pattern

 

 

 

3.

Air holes at burner inlet blocked

3.

Clean out air holes at burner inlet. Peri-

 

 

 

 

odically repeat as needed

 

4.

Burner flame holes blocked

4.

Remove blockage

For..com

111604-01A

Image 24
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationLog Base Assembly Product IdentificationProduct Features Local CodesUnpacking AIR for Combustion and VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installing HoodCheck GAS Type Electrical HookupInstallation Clearances Included with Mantel AccessoryAssembling and Attaching Optional Brass Trim Conventional Fireplace Installation Installing Cabinet MantelBUILT-IN Fireplace Installation Actual Framing Height 32 3 Front Width DepthSupport Bracket Firebox Wrapper Shield Power Screws Cord Installing GAS Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Connecting Fireplace to GAS Supply Gas ConnectionPressure Testing gas Supply Piping system Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Check all other internal joints for leaksInstalling Logs Installing Logs 1For Your Safety Read Before Lighting Installing Batteries in ReceiverInstalling Battery into Remote Operating HeaterManual Lighting Procedure To Turn OFF GAS To ApplianceShutting Off Heater Shutting Off Burners Only pilot stays litHAND-HELD Remote Operation Inspecting Burners Pilot Flame PatternBurner Primary AIR Holes Main BurnerCleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement Wiring Diagram SpecificationsTechnical Service Service HintsIllustrated Parts Breakdown Models LMFP33PRParts List KEY Part Number LMFP33PR LMFP33NR Description QTYFirebox LMFP33PR LMFP33NR Firebox LMFP33PR and LMFP33NR KEY Part Number Description QTYAccessories Blower Accessory GA3750A GA3700TA SeriesEquipment Shutoff Valve GA5010 Information VideoOwners Registration Form Postage Required 111604-01A Warranty Information