Desa LMFP33NR installation manual Product Identification, Log Base Assembly

Page 3

SAFETY INFORMATION PRODUCT IDENTIFICATION

3

SAFETY INFORMATION

Continued

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Lo- cate propane/LP supply tank(s) outdoors (propane/LP units only).

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This fireplace shall not be installed in a bedroom or bathroom.

5.Do not use this fireplace as a wood-burning fireplace. Use only the logs provided with the fireplace.

6.Do not add extra logs or ornaments such as pine cones, ver- miculite, or rock wool. Using these added items can cause soot- ing. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.

7.To prevent the creation of soot, follow the instructions in Clean- ing and Maintenance, page 21.

8.Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these prod- ucts may create a white powder residue within burner box or on adjacent walls or furniture.

9.This fireplace needs fresh air ventilation to run properly. This fireplace has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if enough fresh air is not available. See Air for Combustion and Ventila- tion, pages 4 through 6. If fireplace keeps shutting off, see Troubleshooting, pages 22 through 24.

10.Do not run fireplace

where flammable liquids or vapors are used or stored

under dusty conditions

11.Do not use this fireplace to cook food or burn paper or other objects.

12.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service technician to in- spect the fireplace and to replace any part of the control sys- tem and any gas control which has been under water.

13.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

14.Turn fireplace off and let cool before servicing. Only a quali- fied service person should service and repair fireplace.

15.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

16.To prevent performance problems in propane/LP units, do not use propane/LP fuel tanks of less than 100 lbs. capacity (pro- pane/LP units only).

17.Provide adequate clearances around air openings.

PRODUCT IDENTIFICATION

5-Piece Log Set

Control

Knob

 

O

NO

F

Remote

 

Control

 

Piezo Ignitor

Remote Receiver

Figure 1 - Log Base Assembly

Top Louver

AssemblyTop Outer

Casing

Firebox

Hood

Firebox

Support

Blower Assembly (Optional)

Bottom

Louver

Assembly

Screen

Assembly

Figure 2 - Fireplace (VYGF33PRA Shown)

For morevisit www..com

111604-01A

Image 3
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Log Base AssemblyAIR for Combustion and Ventilation Product FeaturesLocal Codes UnpackingConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Electrical Hookup InstallationInstalling Hood Check GAS TypeInstallation Clearances Included with Mantel AccessoryAssembling and Attaching Optional Brass Trim Installing Cabinet Mantel Conventional Fireplace InstallationActual Framing Height 32 3 Front Width Depth BUILT-IN Fireplace InstallationSupport Bracket Firebox Wrapper Shield Power Screws Cord Installing GAS Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Gas Connection Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing gas Supply Piping systemCheck all other internal joints for leaks Pressure Testing Fireplace Gas ConnectionsInstalling Logs 1 Installing LogsOperating Heater For Your Safety Read Before LightingInstalling Batteries in Receiver Installing Battery into RemoteShutting Off Burners Only pilot stays lit Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterHAND-HELD Remote Operation Main Burner Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesCleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement Service Hints Wiring DiagramSpecifications Technical ServiceModels LMFP33PR Illustrated Parts BreakdownKEY Part Number LMFP33PR LMFP33NR Description QTY Parts ListFirebox LMFP33PR LMFP33NR KEY Part Number Description QTY Firebox LMFP33PR and LMFP33NRInformation Video AccessoriesBlower Accessory GA3750A GA3700TA Series Equipment Shutoff Valve GA5010Owners Registration Form Postage Required 111604-01A Warranty Information