TROUBLESHOOTING
22
TROUBLESHOOTING
Note: For additional help, visit DESA Heating Products’ technical service web site at www.desatech.com.
Note: All troubleshooting items are listed in order of operation.
WARNING: Turn off and let cool before servicing. Only a qualified service person should service and repair heater.
CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.
| OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
| When ignitor button is pressed, there is no | 1. | Ignitor electrode not connected to igni- | 1. | Reconnect ignitor cable |
| spark at ODS/pilot |
| tor cable |
|
|
|
| 2. | Ignitor cable pinched or wet | 2. | Free ignitor cable if pinched by any |
|
|
|
|
| metal or tubing. Keep ignitor cable dry |
|
| 3. | Piezo ignitor nut is loose | 3. | Tighten nut holding piezo ignitor to base |
|
|
|
|
| panel of log set. Nut is located behind |
|
|
|
|
| base panel. |
|
| 4. | Broken ignitor cable | 4. | Replace ignitor cable |
|
| 5. | Bad piezo ignitor | 5. | Replace piezo ignitor |
|
| 6. | Ignitor electrode positioned wrong | 6. | Replace pilot assembly |
|
| 7. | Ignitor electrode broken | 7. | Replace pilot assembly |
|
|
|
|
|
|
| When ignitor button is pressed, there is | 1. | Gas supply turned off or equipment | 1. | Turn on gas supply or open equipment |
| spark at ODS/pilot but no ignition |
| shutoff valve closed |
| shutoff valve |
|
| 2. | Control knob not in PILOT position | 2. | Turn control knob to PILOT position |
|
| 3. | Control knob not pressed in while in | 3. | Press in control knob while in PILOT |
|
|
| PILOT position |
| position |
|
| 4. | Air in gas lines when installed | 4. | Continue holding down control knob. |
|
|
|
|
| Repeat igniting operation until air is |
|
|
|
|
| removed |
|
| 5. | Depleted gas supply (propane/LP only) | 5. | Contact local propane/LP gas company |
|
| 6. | ODS/pilot is clogged | 6. | Clean ODS/pilot (see Cleaning and |
|
|
|
|
| Maintenance, page 21) or replace ODS/ |
|
|
|
|
| pilot assembly |
|
| 7. | Gas regulator setting is not correct | 7. | Replace gas regulator |
|
|
|
|
|
|
| ODS/pilot lights but flame goes out when | 1. | Control knob not fully pressed in | 1. | Press in control knob fully |
| control knob is released | 2. | Control knob not pressed in long enough | 2. | After ODS/pilot lights, keep control |
|
|
|
|
| knob pressed in 30 seconds |
|
| 3. | Equipment shutoff valve not fully open | 3. | Fully open equipment shutoff valve |
|
| 4. | Pilot flame not touching thermocouple, | 4. | A) Contact local natural or propane/LP |
|
|
| which allows thermocouple to cool, |
| gas company |
|
|
| causing pilot flame to go out. This prob- |
|
|
|
|
| lem could be caused by one or both of |
| B) Clean ODS/pilot (see Cleaning and |
|
|
| the following: |
| Maintenance, page 21) or replace ODS/ |
|
|
| A) Low gas pressure |
| pilot assembly |
|
|
| B) Dirty or partially clogged ODS/pilot |
|
|
|
| 5. | Thermocouple connection loose at con- | 5. | Hand tighten until snug, then tighten |
|
|
| trol valve |
| 1/4 turn more |
|
| 6. | Thermocouple damaged | 6. | Replace pilot assembly |
|
| 7. | Control valve damaged | 7. | Replace control valve |
For..com