4.Assemble Chimney Sections

Attach either a straight chimney section or an offset to the top of the fireplace (depending on your installation requirement). Chimney sections are locked together by pushing downward until the top section meets the stop bead on the lower section.

The inner flue is placed to the inside of the flue section below it. The outer casing is placed outside the outer casing of the chimney section below it. See Figure 10.

WARNING!

Carefully follow the instructions for assembly of the pipe and other parts needed to install this fireplace system. Failure to do so may result in a fire, especially if combustibles are too close to the fireplace or chimney and air spaces are blocked, preventing the free movement of cooling air.

5.Install Firestop Spacers

Mark and cut out an opening in the ceiling for the firestop spacer being utilized (17” x 17” for an FS538, 17” x 26” for an FS540). Frame the opening with the same dimension lumber used in the ceiling joists.

Install the firestop spacer.

These firestop spacers are designed to provide the minimum 2” air space required around the chimney. In all situations, the firestop spacers are to be nailed to the ceiling joists from the bottom or fireplace side, EXCEPT when the space above is an insulated ceiling or attic space. In this situation, the firestop spacer must be nailed from the top side to prevent loose insulation from falling into the required 2” air space around the chimney. See Figure 11.

CAUTION:

Firestop spacers must be used whenever the chimney penetrates a ceiling/floor area.

Figure 10

Assembling Chimney

Sections

Figure 11

Installing the Firestop Spacer

01/04

4039-150 Rev B

13

Image 13 Contents
MONTANA-36 and MONTANA-42 Outdoor Woodburning Fireplace Installation & Operating InstructionsTable of Contents Description of the Fireplace System Listings and Code ApprovalsHeat-N-Glo fireplace system consists of the following Optional Components IncludeFireplace Components Fireplace System ComponentsCatalog # Description Chimney ComponentsFirestop Spacer TR11T Fireplace Locations and Space Requirements PRE-INSTALLATION PreparationFrame the Fireplace Construct an Outdoor EnclosureSidewalls/Surrounds Chimney Requirements Using Offsets and ReturnsNumber of Sections Required Chimney Height Requirements above roof linePosition the Fireplace Installation of the FireplacePlace the Protective Metal Hearth Strips Level the FireplaceAssemble Chimney Sections Install Firestop Spacers∅ 6. Attic Insulation Shield Double-check the Chimney AssemblySecure the Chimney System Installing a TR11T Round Telescoping Termination Cap Install the Termination CapInstall the Chimney Air Kit Install the Cooling Air Kit furnishedGas Log/Lighter Provisions Complete the EnclosureFactory Built Hearth Extension Hearth ExtensionFinishing Material Position the Hearth ExtensionMantel Glass DoorsMontana Installation Instructions General Information Flue Damper Operating InstructionsFirescreen GrateWood Fuel Starting a Fire Chimney Cleaning Maintenance InstructionsDisposal of Ashes Creosote and SootHomeowner’s Notes Index Warranty For HEAT-N-GLO Fireplaces