Hearth and Home Technologies Montana-36, Montana-42 PRE-INSTALLATION Preparation

Page 8

MONTANA INSTALLATION INSTRUCTIONS

D. PRE-INSTALLATION PREPARATION

1.Fireplace Locations and Space Requirements

This fireplace is intended for installation on an outdoor patio or in your yard. It must never be installed inside of the warm air envelope of your structure. Significant cold air infiltration will result if it is installed inside of the structure. Figure 2 shows two typical installations.

Figures 3 and 4 show two typical installations assuming an outside air kit is being used. Therefore, an allowance must be made for 90° bends. Less space is required when ducting goes directly outside without forming elbows.

Figure 2 - Fireplace Locations

Note: If the fireplace is a freestanding fireplace, it must be located a minimum of 10’ from a combustible struc- ture.

A minimum height of 6’ 4” measured from the base of the fireplace to the bottom of the termination cap is permit- ted in this installation.

These are rough framing dimensions only.

CLEARANCES!

A minimum 1½” air clearance must be maintained at the back and sides of the fireplace assembly ex- cept at the nailing flange where the clearance is ½”.

Chimney sections at any level require a 2” minimum air space clearance between the framing and chim- ney section.

Figure 3 - Installation Along a Wall

Figure 4 - Corner Installation

or an Exterior Chase

 

WARNING!

To prevent contact with sagging or loose insulation, the fireplace must not be installed against vapor barriers or exposed insulation. Localized overheating could occur and a fire could result.

8

4039-150 Rev B

01/04

Image 8 Contents
Installation & Operating Instructions MONTANA-36 and MONTANA-42 Outdoor Woodburning FireplaceTable of Contents Listings and Code Approvals Description of the Fireplace SystemHeat-N-Glo fireplace system consists of the following Optional Components IncludeFireplace System Components Fireplace ComponentsChimney Components Catalog # DescriptionFirestop Spacer TR11T PRE-INSTALLATION Preparation Fireplace Locations and Space RequirementsSidewalls/Surrounds Construct an Outdoor EnclosureFrame the Fireplace Using Offsets and Returns Chimney RequirementsChimney Height Requirements above roof line Number of Sections RequiredInstallation of the Fireplace Position the FireplacePlace the Protective Metal Hearth Strips Level the FireplaceInstall Firestop Spacers Assemble Chimney SectionsSecure the Chimney System Double-check the Chimney Assembly∅ 6. Attic Insulation Shield Install the Termination Cap Installing a TR11T Round Telescoping Termination CapInstall the Cooling Air Kit furnished Install the Chimney Air KitComplete the Enclosure Gas Log/Lighter ProvisionsHearth Extension Factory Built Hearth ExtensionPosition the Hearth Extension Finishing MaterialMantel Glass DoorsMontana Installation Instructions Operating Instructions General Information Flue DamperGrate FirescreenWood Fuel Starting a Fire Maintenance Instructions Chimney CleaningDisposal of Ashes Creosote and SootHomeowner’s Notes Index Warranty For HEAT-N-GLO Fireplaces
Related manuals
Manual 28 pages 44.42 Kb