Hearth and Home Technologies Montana-36 Installation of the Fireplace, Position the Fireplace

Page 12

MONTANA INSTALLATION INSTRUCTIONS

F. INSTALLATION OF THE FIREPLACE

WARNING!

Before starting, do the following:

1.Wear gloves and safety glasses for protection.

2.Keep hand tools in good condition. Sharpen cutting edges and make sure tool handles are secure.

3.Always maintain the minimum air space required to the enclosure to prevent fire.

1.Position the Fireplace

This fireplace may be placed on either a combustible or noncombustible continuous flat surface. Follow the instructions for framing on pages 8 and 9. Slide the fireplace into position. Be sure to provide the minimum air clearance at the sides and back of the fireplace assembly.

2.Place the Protective Metal Hearth Strips

Included with your fireplace you will find two metal hearth strips measuring approximately 28” x 4”. These strips are used to provide added protection where the fireplace and the hearth extension meet.

Slide each metal strip 2” under the front edge of the fireplace. The individual pieces must overlap each other by 1” minimum in the middle of the fireplace to provide continuous coverage of the floor. See Figure 9. These metal strips should extend from the front and sides of the fireplace opening by 2”.

3.Level the Fireplace

Level the fireplace side-to-side and front-to-back. Shim with

Figure 9 - Positioning the Metal Strips

 

noncombustible material, such as sheet metal, as necessary.

 

Secure the fireplace (using the nailing flanges located on either

 

side of the fireplace) to the vertical framing.

 

 

 

 

 

 

Important: To ensure proper fit of the glass doors,

 

 

 

check the fireplace opening for square. Measure

 

 

 

diagonal distances of the opening to make sure they

 

 

 

are equal. If they are not equal, continue to shim

 

 

 

the fireplace until those diagonals are equal.

 

 

 

 

 

 

12

4039-150 Rev B

01/04

Image 12
Contents Installation & Operating Instructions MONTANA-36 and MONTANA-42 Outdoor Woodburning FireplaceTable of Contents Listings and Code Approvals Description of the Fireplace SystemHeat-N-Glo fireplace system consists of the following Optional Components IncludeFireplace System Components Fireplace ComponentsChimney Components Catalog # DescriptionFirestop Spacer TR11T PRE-INSTALLATION Preparation Fireplace Locations and Space RequirementsConstruct an Outdoor Enclosure Frame the FireplaceSidewalls/Surrounds Using Offsets and Returns Chimney RequirementsChimney Height Requirements above roof line Number of Sections RequiredInstallation of the Fireplace Position the FireplacePlace the Protective Metal Hearth Strips Level the FireplaceInstall Firestop Spacers Assemble Chimney SectionsDouble-check the Chimney Assembly ∅ 6. Attic Insulation ShieldSecure the Chimney System Install the Termination Cap Installing a TR11T Round Telescoping Termination CapInstall the Cooling Air Kit furnished Install the Chimney Air KitComplete the Enclosure Gas Log/Lighter ProvisionsHearth Extension Factory Built Hearth ExtensionPosition the Hearth Extension Finishing MaterialMantel Glass DoorsMontana Installation Instructions Operating Instructions General Information Flue DamperGrate FirescreenWood Fuel Starting a Fire Maintenance Instructions Chimney CleaningDisposal of Ashes Creosote and SootHomeowner’s Notes Index Warranty For HEAT-N-GLO Fireplaces