DCS BGB36, BGB48 Burner Adjustment, Grill Burner AIR Adjustment, Grill Burner Flame Height

Page 21

INSTALLATION

BURNER ADJUSTMENT

Burner adjustment should only be performed by a licenced gas fitter.

GRILL BURNER AIR ADJUSTMENT:

Each grill burner is tested and adjusted at the factory prior to shipment; however, variations in the local gas supply or a conversion from one gas to another may make it necessary to adjust the burners. The flames of the burners (except the rotisserie burner) should be visually checked and compared to that of the drawing in Fig.21. Flames should be blue and stable with no yellow tips (LPG units may have some yellow tipping), excessive noise or lifting. If any of these conditions exist, check if the air shutter or burner ports are blocked by dirt, debris, spider webs, etc. Proceed with air shutter adjustment. The amount of air which enters a burner is governed by a metal cap at the inlet of the burner called an air shutter. It is locked in place by a screw which must be loosened prior to lighting the burner for adjustment.

GRILL BURNER FLAME HEIGHT:

Before beginning, ensure the grill is OFF and cool. To access the grill burner air shutters, first remove the grates, grease shields and radiants from the firebox, then remove the grill burner using instructions shown in section ‘Care and maintenance’. With a screw driver, loosen the lock screw on the face of the air shutter slightly so that the air shutter can be adjusted.

To Adjust:

1.Be careful as the burner may be very hot.

2.If the flame is yellow, indicating insufficient air, turn the air shutter counterclockwise to allow more air to the burner.

 

38 mm

10 mm

CLOSE

OPEN

 

FIG. 21 Burner Flame

Height

3.If the flame is noisy and tends to lift away from the burner, indicating too much air, turn the air shutter clockwise.

Reinstall the grill burner, ensuring the burner is level. Light the burner and check the flame. If all is okay, remove the burner (CAUTION - burner may be hot, allow time to cool) and tighten the air shutter screw. If not repeat the above procedure to readjust the air shutter.

LOW FLAME SETTING ADJUSTMENT:

The valves on the grill feature an adjustable low setting. Due to fluctuations in gas pressure, heating value or gas conversion, you may feel it necessary to increase or decrease gas flow in the low position. We do not recommend adjusting the infrared rotisserie burner.

To Adjust:

1.Light the burner.

2.Turn the control knob to the lowest setting (all the way counter-clockwise).

3.Remove the knob.

4.While holding the valve shaft with pliers, insert a thin, flat tipped screwdriver into the shaft and while viewing the burner adjust to a minimum stable flame (Fig. 22).

SIDE BURNER FLAME HEIGHT:

The correct height of the flame mainly depends on the size of the bottom of the cooking utensil, the material of the cooking utensil, the amount and type of food and the amount of liquid in the utensil. Following are some basic rules for selecting flame height.

For safety reasons the flame must never extend beyond the bottom of the cooking utensil. Never allow flames to curl up the side of the pan (see Fig. 23).

Utensils which conduct heat slowly (such as glass-ceramic) should be used with me- dium to low flames. If you are cooking with a large amount of liquid, a slightly larger flame can be used.

FIG. 22 Low Setting Adjustment

Proper Flame Height

Fig. 23

WARNING: IMPORTANT!

If, after following the instructions above, the burners still cannot be adjusted to perform correctly, the appliance must not be used. Contact Customer Care. Before lighting, inspect the gas supply piping or hose prior to turning the gas “on”. If there is evidence of cuts, wear, or abrasion, it must be replaced prior to use.

19

Image 21
Contents User guide Page Please Retain this Manual for Future Reference Message to OUR CustomersTable of Contents Important Safety Notice Safety Practices & PrecautionsSafety Practices & Precautions Flame Burner Grill PlacementSafety Practices & Precautions BGB36-BQAR Grill ModelsInstallation Locating GRILL/BUILT-IN ClearancesLocation Installation Clearances to Non-Combustible Construction Clearances to Non-Combustible ConstructionClearances to Combustible Construction GeneralInsulated Jacket BUILT-IN Construction Details GAS Requirements GAS HOOK-UPConnection with rigid piping Checking the GAS PressureLPG Cylinder Requirements LPG GAS Hook UPMax LPG Cylinder Restraint for BUILT-IN InstallationStep Leak Testing -- Procedure for a Qualified GAS Fitter Before TestingTo Test Grill Burner AIR Adjustment Burner AdjustmentLOW Flame Setting Adjustment Grill Burner Flame HeightRadiant Assembly Installing the Grease ShieldsRadiant Assembly Installation Griddle plate to be fitted to centre burner positions only Griddle PlateThese Instructions Installer ChecklistTag location Model # and Serial # Using the Grill Lighting InstructionsTo Light Side Burners 48BQR Models only Grill GrillingDIRECT/INDIRECT Cooking Notes BurnerDUAL-SIDED Grates Grilling HintsShaped Grate Radius Grate ROD Using the RotisserieRecommended PreparationWorking Area Meat PreparationManual Lighting To Light the Rotisserie Burner Before CookingCooking on Rotisserie Care and Maintenance General AdviceRecommended Maintenance Schedule Leak Testing Procedure for the User Battery Replacement Regulator and Hose ReplacementGrill Grates Heat Shields Ceramic RodsDrip PAN Grease TrayCare and Maintenance To Remove the Grill Burners for Cleaning Stainless SteelSide Burner Ignitors Grill Burner Cleaning Injector CleaningTo Replace the Grill Burners After Cleaning Side Burners BGB48 BQR Model Side Burner Grates BGB48 BQR ModelBefore Calling for Service TroubleshootingGrill WON’T Light When the Ignition Button is Pushed LOW Heat with Knob in HI/SEAR PositionContact US Through OUR Local Website ServiceCall US TOLL-FREE, 24/7 Write to USPage Warranty Page NZ AU