DCS BGB48, BGB36 Leak Testing -- Procedure for a Qualified GAS Fitter, Before Testing, To Test

Page 20

INSTALLATION

LEAK TESTING -- PROCEDURE FOR A QUALIFIED GAS FITTER

Important!

There are two levels of testing for leaks. (1) Gas supply connection points that are accessible with the grill installed can be leak tested by the user. (2) Connections that are internal to the grill and therefore require dis- assembly should only be leak-tested by a licenced gas fitter. The full procedure below is to be performed by a licenced gas fitter only. Leak testing instructions for the user are in section ‘Care and maintenance’.

GENERAL:

Although all gas connections on the grill are leak tested at the factory prior to shipment, a complete gas tightness check must be performed at the installation site by a qualified gas fitter due to possible mishandling in shipment, or excessive pressure unknowingly being applied to the unit. Check the whole system for leaks, or immediately check if the smell of gas is detected.

Before Testing:

Do not smoke while leak testing. Extinguish all open flames. Never leak test with an open flame. Make a soap solution of one part liquid detergent and one part water. You will need a spray bottle, brush, or rag to apply the solution to the fittings. For LPG units, check with a full cylinder. The valve panel must be removed to check the valves and fittings. Remove the knobs and the safety valve knob, then remove the 2 screws which fasten the valve panel to the unit (you will need a Philips screw driver for this). Pull the valve panel outward and unplug the wires from the ignition module and the back of the ignition button. In the back of the unit remove the screws which hold the service panel in place. Remove the service panel.

To Test:

Make sure all control valves are in the “OFF” position. Turn the gas supply “ON”. Check all connections from the supply line, or LPG cylinder up to and including the manifold pipe assembly. Apply the soap solution around the connection, valve, tubing and end of the manifold. Soap bubbles will appear where a leak is present. If a leak is present, immediately turn off gas supply, tighten any leaking connections, turn gas on, and recheck. Check all the gas connections at the base of the control valves where they screw into the manifold pipe.

To check rotisserie burner and safety valve the burner must be lit, then leak test the connections located behind the service panel. If you cannot stop a gas leak turn off the gas supply and call your local gas utility, or the dealer you purchased the appliance from. Only those parts recommended by the manufacturer should be used on the grill. Substitution can void the warranty.

WARNING!

Do not use the grill until all connections have been checked and do not leak.

Check all gas supply fittings for leaks before each use. Keep a spray bottle of soapy water near the gas supply shut-off valve. Spray all the fittings. Bubbles indicate leaks (Fig. 19 & 20).

LEAK TEST POINTS

CHECK HOSE FOR

SIGNS OF ABRASIONS,

CRACKS, OR LEAKS

Bottom of unit

LEAK TEST POINTS

FIG. 19 LPG Gas

FIG. 20 Nat. Gas

18

Image 20
Contents User guide Page Message to OUR Customers Please Retain this Manual for Future ReferenceTable of Contents Safety Practices & Precautions Important Safety NoticeSafety Practices & Precautions Grill Placement Flame BurnerSafety Practices & Precautions Grill Models BGB36-BQARLocation InstallationLocating GRILL/BUILT-IN Clearances Installation Clearances to Non-Combustible Construction Clearances to Non-Combustible ConstructionInsulated Jacket Clearances to Combustible ConstructionGeneral BUILT-IN Construction Details GAS HOOK-UP GAS RequirementsChecking the GAS Pressure Connection with rigid pipingLPG GAS Hook UP LPG Cylinder RequirementsLPG Cylinder Restraint for BUILT-IN Installation MaxStep To Test Leak Testing -- Procedure for a Qualified GAS FitterBefore Testing Burner Adjustment Grill Burner AIR AdjustmentLOW Flame Setting Adjustment Grill Burner Flame HeightRadiant Assembly Installation Radiant AssemblyInstalling the Grease Shields Griddle Plate Griddle plate to be fitted to centre burner positions onlyInstaller Checklist These InstructionsTag location Model # and Serial # To Light Side Burners 48BQR Models only Using the GrillLighting Instructions Grilling GrillDIRECT/INDIRECT Cooking Notes BurnerGrilling Hints DUAL-SIDED GratesShaped Grate Radius Grate Using the Rotisserie RODPreparation RecommendedWorking Area Meat PreparationTo Light the Rotisserie Burner Before Cooking Manual LightingCooking on Rotisserie Recommended Maintenance Schedule Care and MaintenanceGeneral Advice Leak Testing Procedure for the User Grill Grates Battery ReplacementRegulator and Hose Replacement Ceramic Rods Heat ShieldsGrease Tray Drip PANCare and Maintenance Side Burner Ignitors To Remove the Grill Burners for CleaningStainless Steel To Replace the Grill Burners After Cleaning Grill Burner CleaningInjector Cleaning Side Burner Grates BGB48 BQR Model Side Burners BGB48 BQR ModelTroubleshooting Before Calling for ServiceGrill WON’T Light When the Ignition Button is Pushed LOW Heat with Knob in HI/SEAR PositionService Contact US Through OUR Local WebsiteCall US TOLL-FREE, 24/7 Write to USPage Warranty Page NZ AU