| Figure 1 (Natural gas model only) | |
IMPORTANT: your Kenmore Natural Gas Grill cannot |
| |
be converted to use LP Gas. Attempting to do so | GAS SUPPLY | |
| ||
is extremely hazardous and will also void the grill | INSIDE | |
WALL | ||
warranty. | ||
| ||
| OUTSIDE |
Your natural gas grill is designed to operate on natural gas only, at a pressure of 7" water column (W.C.) (1/4 psi or 1.75 kpa), regulated at the residential meter. Check with your gas utility company for local gas pressure and with your local municipality for building code requirements. If your residential gas line pressure has not been regulated to 7" W.C., contact your local gas utility company for professional assistance.
WALL
TO GRILL
LOCKING | SHUT OFF |
It is recommended that a Shutoff Valve be installed
at the gas supply source outdoors. Install at a point after the gas pipe exits the outside wall and before
the
See Fig. 1.
•Pipe sealing compound or pipe thread tape resistant to the action of natural gas must be used on all male
pipe threads when making the connection.
Disconnect your gas grill from fuel source when the gas supply is being tested at high pressures. This gas grill and its individual shutoff valve must be disconnected from the gas supply pipe system during any pressure testing of that system at pressure in excess of 1/2 psi (3.5kpa).
Turn off your gas grill when the gas supply is being tested at low pressures. The grill must be isolated from the gas supply pipe system by closing its individual manual shutoff valve during any pressure testing of the gas supply pipe system at pressures equal to or less than 1/2 psi (3.5kpa).
QUICK DISCONNECT