Aussie 6805, 6804 manual How to Perform a Leak Test First Time USE and as required

Page 20

20

How to Perform A Leak Test “FIRST TIME USE” and as required

Supplies Needed for a Leak Test:

Clean paint brush

Water

Dish washing liquid

1.Use an LP Gas Cylinder equipped with an OPD (Overfill Prevention Device) and have it filled at an authorized LP gas dealer by a qualified attendant.

2.Make sure all grill Control Panel Knobs are turned to the “Off” position and verify that the LP Gas Cylinder valve is closed by turning the knob on the LP Gas Cylinder clockwise until it stops.

3.Mix one part of water with one part of dish washing liquid.

4.Figures 1, 2, 4 and 4a show the grill at assembly step 11, prior to attaching the Side Tables.and illustrate the initial steps in the “FIRST TIME USE LEAK TEST”.

Detach the Control Panel from the Grill Body/Firebox by removing the two 5/32” Bolts from each end. (Fig. 1) Gently pull the Control Panel away from the Body until Valves disengage from the Tubular burner ends. (Fig. 2) Support the Control Panel to keep tension off of the igniter wire leads or detach the wire leads from the Starter Button module.

Tubular Burner

Ends

Fig. 1

Fig. 2

5. With the regulator hose connected to the LP Gas Cylinder, turn the knob on the Cylinder counterclockwise. (Fig. 3)

Coupling Nut

Check for leaks at

 

 

Cylinder Valve and

 

Regulator Connection

 

and Fittings

Fig. 3

Fig. 3a

!CAUTION

To reduce the risk of a laceration hazard:

• Wear protective gloves when removing or replacing Control panel, which could have sharp edges.

Image 20
Contents 68046805 For Outdoor Household Use Only. Not for Commercial UseTools Required for Assembly Supplied with Grill Carbon Monoxide HazardContents Preparation for AssemblyPacking List- Model Box DescriptionPacking List- Model Step Cabinet Bottom Assembly Assembly InstructionsStep Caster Assembly Step Side Panel Assembly Step Front Crossbar Assembly Step Cabinet Upright AssemblyStep Cylinder Guard Assembly Cylinder Blocking Wire AssemblyCenter Wheel Assembly Model Door Handle Assembly StepStep Drawer Assembly Drawer PositioningStep Door Assembly Step Hood/Body To Cart AssemblyStep Side Table Assembly Side Burner Valve Assembly Side Burner Valve ConnectionSide Burner Grid Assembly Step Side Burner Igniter Wire ConnectionStep Side Burner Control Knob Assembly Step Warming Rack Assembly Step Bottom Body Panel AssemblyFoil Pan/Grease Pan Assembly Step Flame Diffuser/Cooking Grid Assembly Step Battery in Igniter InstallationLP Gas Cylinder Connecting/Disconnecting the GasUsing Gas Connecting LP Gas Cylinder LP Hose and RegulatorBefore Using Your LP Gas Grill Installation CodesSelecting a Location Performing a Leak TestHow to Perform a Leak Test First Time USE and as required Model Lighting the Grill Using the Pulse-Spark Ignitor Off positionLighting the Side Burner Sear Burner or Rotisserie Burner Manual Lighting of the Grill onManually Lighting the Grill Manually Lighting the Side Burner Lighting the Side BurnerCheck The Flame Manually Lighting the Side Burner Cooking On the Gas Grill Grill Cooking Direct MethodIndirect Cooking Roasting Roasting Indirect MethodDirect Cooking on the Grids Warming Rack End of Cooking SessionCare and Maintenance Cleaning the GrillHow to Clean the Burners Open up Storage Troubleshooting EmergenciesSee How to Clean Burners in Care and Maintenance Then stops when full Rises up while fillingParts Illustration- Model Parts List- Model Key Description QuantityParts Illustrations- Model Limited Warranty Meco Corporation Limited Warranty