35
Troubleshooting
Problem |
| Possible Cause |
| Solution |
Regulator coupling nut is not fully connected to LP cylinder
Vapor lock in connections
Tighten coupling nut by hand about
Turn Control Knobs to “Off” position and turn LP Gas Cyl- inder handle clockwise until it stops. Wait five minutes. Relight LP gas grill. If flame continues to be low, turn off gas at LP Gas Cylinder and grill. Disconnect the regulator from the LP Gas Cylinder. Reconnect the regulator to the LP Gas Cylinder. This will reset the excess flow valve Perform a leak test. Relight grill.
|
| Obstructions in Burners |
|
| Wet Electrodes and Burners |
|
| Wire loose or disconnected |
|
| Wire shorting (sparking |
|
| between Igniter and Electrode) |
|
|
|
IR side burner will not |
| Thermocouple is not properly |
stay lit |
| attached to side burner valve. |
|
| Safety sensor is not completely |
|
| heated |
|
|
|
IR side burner will not |
| IR side Burner has filled with |
light using ignitor or |
| water |
match |
|
|
|
|
|
Burners will not light |
| Burners not assembled correctly |
using a match |
|
|
|
| LP Gas Cylinder is empty |
|
| |
|
| regulator |
Clean the Burners. See “How to Clean Burners” in Care and Maintenance.
Dry Electrode with clean cloth. Air dry or use blow dryer.
Reconnect the wire.
Replace Igniter Wire/Electrode assembly. (Call the Customer Service Department)
See Step 14C Page 13
Follow lighting proceedure but hold control knob IN for at least 10 seconds.
Blow water out of ceramic center of burner.
Close lid when not in use.
See
Take LP Gas Cylinder to licensed LP gas supplier to be refilled.
Turn Control Knobs to “Off” position and turn LP Gas Cyl- inder handle clockwise until it stops. Wait five minutes. Relight LP gas grill. If flame continues to be low, turn off gas at LP Gas Cylinder and grill. Disconnect the regulator from the LP Gas Cylinder. Reconnect the regulator to the LP Gas Cylinder. This will reset the excess flow valve Perform a leak test. Relight grill.
Regulator Coupling nut is not fully connected to LP Gas Cylinder
Obstructions in Burners
Low flame or low heat
Excess flow valve tripped in regulator
Tighten Regulator Coupling nut by hand about
See “How to Clean Burners” in Care and Maintenance.
Check LP Gas Cylinder. Refill if necessary.
Turn Control Knobs to “Off” position and turn LP Gas Cyl- inder handle clockwise until it stops. Wait five minutes. Relight LP gas grill. If flame continues to be low, turn off gas at LP Gas Cylinder and grill. Disconnect the regulator from the LP Gas Cylinder. Reconnect the regulator to the LP Gas Cylinder. This will reset the excess flow valve Perform a leak test. Relight grill.