Aussie 6805, 6804 manual Emergencies, Troubleshooting

Page 34

34

Emergencies

Problem

Gas leaking from cracked/cut/burned hose

Gas leaking from

LP Gas Cylinder

Gas leaking from LP Gas Cylinder valve

Gas leaking between

LP Gas Cylinder and regula- tor connection

Fire coming through Control Panel

Grease fire or excessive flames above cooking surface

Flashback (Fire in or around Venturi tubes)

Possible Cause

Damaged hose

Mechanical failure due to rust or mishandling

Failure of valve from mishan- dling or mechanical malfunc- tion

Improper installation, con- nection not tight, failure of seal on LP Gas Cylinder valve

Fire in or around Venturi tube section of Burner

Too much grease build-up in Burner section

Clogged or blocked Venturi tube

Solution

Turn off gas at the LP Gas Cylinder. Replace valve/hose regulator before continuing use.

Replace LP Gas Cylinder.

Turn off LP Gas Cylinder valve. Return Cylinder to gas supplier.

Turn off LP Gas Cylinder valve. Re-install correctly or tighten coupling nut. Replace Cylinder if seal is dam- aged. See “Leak Test” and “Connecting Regulator to LP Gas Cylinder” sections.

If you can safely reach the Control Panel, turn off Control Knobs, then close the LP Gas Cylinder valve. Once fire is out and grill has cooled off, remove Burner(s) and inspect for blockage from spider webs/insect nests or rust. See “How to Clean Burners” section. Replace any damaged parts.

Turn off Control Knobs and LP Gas Cylinder valve. Once fire is out and grill has cooled off. Clean residual food particles and excess grease from inside firebox area, grease cup, and other surfaces.

If you can safely reach the Control Panel, turn Control Knobs to “Off,” then close the LP Gas Cylinder valve. Clean Burner and Venturi tubes. See “How to Clean

Burners” section.

 

 

 

 

 

 

 

 

 

 

 

 

Troubleshooting

Problem

Possible Cause

 

Solution

 

 

 

 

 

Burners will not light using

Burners not assembled correctly

 

See re-assembly after cleaning in

the ignitor

 

 

 

“Care and Maintenance.”

 

Not holding ignitor switch long

 

When lighting the first (LEFT MOST) Burner, push Control

 

enough for pulse spark

 

Knob in and turn counterclockwise to the “High” position.

 

 

 

 

Depress the Igniter Button until the Burner lights.

 

No spark, electrode cracked,

1.

Make sure all the wires are connected and to the right

 

broken or loose.

 

 

terminals.

 

 

 

2.

If Electronic, check the battery. Make sure it is pushed in

 

 

 

 

 

the holder.

 

 

 

3.

Gas collector tab is bent (making too large or small of

 

 

 

 

 

a gap between the Electrode and tab). By hand, bend

 

 

 

 

 

gas collector tab back within a maximum of 3/16” gap

 

 

 

 

 

to Electrode. (Page 23)

 

 

 

4.

Tighten Electrode mounting screws.

 

 

 

5.

Replace damaged Electrodes.

 

LP gas cylinder is empty

 

Take LP Gas Cylinder to licensed LP gas supplier to be refilled.

Image 34
Contents 68046805 For Outdoor Household Use Only. Not for Commercial UseTools Required for Assembly Supplied with Grill Carbon Monoxide HazardContents Preparation for AssemblyPacking List- Model Box DescriptionPacking List- Model Step Caster Assembly Assembly InstructionsStep Cabinet Bottom Assembly Step Side Panel Assembly Step Front Crossbar Assembly Step Cabinet Upright AssemblyCenter Wheel Assembly Model Door Handle Assembly Step Cylinder Guard AssemblyCylinder Blocking Wire Assembly StepStep Drawer Assembly Drawer PositioningStep Door Assembly Step Hood/Body To Cart AssemblyStep Side Table Assembly Side Burner Valve Assembly Side Burner Valve ConnectionStep Side Burner Control Knob Assembly Step Side Burner Igniter Wire ConnectionSide Burner Grid Assembly Foil Pan/Grease Pan Assembly Step Bottom Body Panel AssemblyStep Warming Rack Assembly Step Flame Diffuser/Cooking Grid Assembly Step Battery in Igniter InstallationUsing Gas Connecting/Disconnecting the GasLP Gas Cylinder Connecting LP Gas Cylinder LP Hose and RegulatorSelecting a Location Before Using Your LP Gas GrillInstallation Codes Performing a Leak TestHow to Perform a Leak Test First Time USE and as required Model Lighting the Grill Using the Pulse-Spark Ignitor Off positionLighting the Side Burner Sear Burner or Rotisserie Burner Manual Lighting of the Grill onManually Lighting the Grill Check The Flame Lighting the Side BurnerManually Lighting the Side Burner Manually Lighting the Side Burner Cooking On the Gas Grill Grill Cooking Direct MethodDirect Cooking on the Grids Roasting Indirect MethodIndirect Cooking Roasting Warming Rack End of Cooking SessionCare and Maintenance Cleaning the GrillHow to Clean the Burners Open up Storage Troubleshooting EmergenciesSee How to Clean Burners in Care and Maintenance Then stops when full Rises up while fillingParts Illustration- Model Parts List- Model Key Description QuantityParts Illustrations- Model Limited Warranty Meco Corporation Limited Warranty