2Wire s8300, g700 manual Display COS Class of Servicedis-cosall, Pen =

Page 17

Display COS (Class of Service):<dis-cos:all;

H500:

AMO COS

STARTED

 

 

 

 

+------

+

------------

+------------

+

------------

+

COS

VOICE

DTE

FAX

+------

+

------------

+------------

+

------------

+

100

 

 

 

MDR

 

 

TTT

 

 

 

 

 

+------

+

------------

+------------

+

------------

+

AMO-COS

 

-111

CLASSES OF SERVICE, SWITCHING UNIT

Add Trunk Members:

<add-tcsu(Trunk Configuration Switching Unit)

PEN = 1-1-73-24

NO = ?

NO: NUMBER OF TRUNKS TO BE CREATED

CHARACTERISTIC : OPTIONAL

POSSIBLE VALUES : 1-30

NO = 23

COTNO = 100

COPNO = 100

DPLN = 0

ITR = 0

TGRP = 100

ACDATA =

?

 

 

ACDATA

 

: DATA ACCESS CLASS

CHARACTERISTIC

: OPTIONAL

POSSIBLE

VALUES :

0-255

ACDATA =

 

 

 

CCT = ?

 

 

 

CCT

 

: CIRCUIT/TRUNK NUMBER

CHARACTERISTIC

: OPTIONAL

POSSIBLE

VALUES : MAX. OF 8 POSITIONS

CCT =

 

 

 

ACT = n

 

 

 

DITIDX =

?

 

 

DITIDX

 

: INDEX TO HOTLINE TABLE FOR DIT TRUNK DESTINATION NUMBER

CHARACTERISTIC

: OPTIONAL

POSSIBLE

VALUES : 0-255

DITIDX =

 

 

 

TRKID = ?

TRKID: TRUNK IDENTIFICATION NUMBER

CHARACTERISTIC : OPTIONAL

POSSIBLE VALUES : 0-9999

TRKID =

Jsl

© 2002 Avaya Inc All Rights Reserved

IP Enabling Siemens

 

 

Hicom with Avaya

 

 

MultiVantage Solutions

LPH 11-27-02

 

17

Image 17
Contents Abstract Avaya S8300/G700 and Siemens Hicom IntroductionSiemens Hicom Equipment and Software ValidatedS8300/G700 Configurations Cable schematicSiemens TMDN64P 25 pair amphenol MM710 RJ45MM710 DS1 Circuit Pack Administration Trunk-Group Administration Assign trunk Group Members Hicom ConfigurationsDetermine If System Has Capacities Displays System DimensionsDis-dimen Dis-dimenltg=30 Adding a TNDN64 T-1 Boardadd-bcsu=10 Mos=30000 =1000=260 = yesDis-bcsutmd Display BoardDisplay Cabinet Dis-bcsutbl TMDN64PNone Add Trunk Group Access CodesAdd-tgacc Add-cop Display Trunk Group Access Codesdis-tgaccAdd COP Class of Parameters Display COT Class of Trunkdis-cot Display COP Class of Parametersdis-copAdd COT Class of Trunkadd-cot VCE Service Module Access VCE Add COS Class of ServiceAdd-cos Copycos =Classes of SERVICE, Switching Unit VCE Service Module Access VCE Ddte = Dfax =AMO COS Started Number of the Class of Service Added is PEN = Display COS Class of Servicedis-cosallDid Direct Inward Dialing Trunk Srtidx = ? Accunet 64 C Accunet 64 RAccunet Didcr Did Conversion TableATT5E8 AT&T 5ESSSOFTWARE Generic 5E7/8 Modify D-Channel from DefaultCha-tcsu NI2 National Isdn Protocol would be NI2 if using National IsdnDisplay Trunk Membersdis-tscu VerificationConclusion