2Wire s8300, g700 manual Equipment and Software Validated, Siemens Hicom

Page 3

2. Equipment and Software Validated:

The configuration used to test performance of this solution was established in an Avaya Lab setting within the guidelines and use parameters allowed in the user licenses acquired with the equipment and software listed below.

Platform

Version

 

 

Avaya MultiVantage Software

1.2

Avaya S8300 Media Server

213.0

Avaya G700 Media Gateway

3.12

Avaya™ 4612 IP Phones

46XXCommon.V36

Avaya™ 4624 IP Phones

46XXCommon.V36

Avaya MM710 T-1 Interface

Firmware version 5

Siemens Hicom 300 30 EP

Release 9006.5

DSC80 Processor

Firmware version D961-D

TMDN64P T-1 Interface (Q2484-X)

Firmware version D467-C

Optiset E Digital Advanced Plus Phones

Model 69671

3. Requirements:

Avaya S8300 Media Server and an Avaya G700 Media Gateway:

Software:

1.

Avaya MultiVantage Software

Release 1.2

or newer

2.

G700 Media Gateway Firmware

Release 3.12

or newer

3.

S8300 Media Server Software

Release 213.0

or newer

Hardware:

1.MM710 DS1 Circuit pack. Installer needs to determine the number of trunks cards that will be needed for traffic requirements. Consideration must be made for the available slots and resources of the Hicom.

2.T-1 Interface cable. Connects the MM710 T-1 RJ45 interface port or the TN464 DS1 circuit pack to the Hicom. The actual cable needs to be custom built.

Siemens Hicom 300:

For this application to be successful, the intended switch must have:

1.Available slots for the T-1 boards.

2.Available purchased software ports for the T-1 spans.

3.T-1 boards must be compatible to software version.

4.If software or port capacities need to be upgraded, there are two options.

a.Siemens can be contacted and they will upgrade the system.

b.The software on DAT tape is purchased from Siemens or a vendor. The customer loads the software.

Jsl

© 2002 Avaya Inc All Rights Reserved

IP Enabling Siemens

 

 

Hicom with Avaya

 

 

MultiVantage Solutions

LPH 11-27-02

 

3

Image 3
Contents Abstract Avaya S8300/G700 and Siemens Hicom IntroductionSiemens Hicom Equipment and Software ValidatedMM710 RJ45 Cable schematicS8300/G700 Configurations Siemens TMDN64P 25 pair amphenolMM710 DS1 Circuit Pack Administration Trunk-Group Administration Assign trunk Group Members Hicom ConfigurationsDis-dimenltg Displays System DimensionsDetermine If System Has Capacities Dis-dimenMos Adding a TNDN64 T-1 Boardadd-bcsu=30 =10= yes =1000=30000 =260TMDN64P Display BoardDis-bcsutmd Display Cabinet Dis-bcsutblAdd Trunk Group Access Codes Add-tgaccNone Display Trunk Group Access Codesdis-tgacc Add COP Class of ParametersAdd-cop Display COP Class of Parametersdis-cop Add COT Class of Trunkadd-cotDisplay COT Class of Trunkdis-cot Copycos = Add COS Class of ServiceVCE Service Module Access VCE Add-cosVCE Service Module Access VCE Ddte = Dfax = AMO COS Started Number of the Class of Service Added isClasses of SERVICE, Switching Unit PEN = Display COS Class of Servicedis-cosallDid Direct Inward Dialing Trunk Srtidx = ? Didcr Did Conversion Table Accunet 64 RAccunet 64 C AccunetModify D-Channel from Default Cha-tcsuATT5E8 AT&T 5ESSSOFTWARE Generic 5E7/8 NI2 National Isdn Protocol would be NI2 if using National IsdnVerification ConclusionDisplay Trunk Membersdis-tscu