2Wire g700, s8300 manual Determine If System Has Capacities, Dis-dimen, Displays System Dimensions

Page 8

Determine If System Has Capacities:

 

 

 

 

 

 

 

<dis-dimen;

(Displays System Dimensions)

 

 

 

 

 

 

TYPE = cc;

 

 

 

 

 

 

 

 

 

 

DIS-DIMEN:CC;

 

 

 

 

 

 

 

 

 

 

H500: AMO DIMEN STARTED

 

 

 

 

 

 

 

 

 

+------------------------------------

 

+------------------------------------

 

 

 

 

 

+

NON-CONFIGURABLE PARAMETERS

 

 

 

 

+------------------------------------

 

+------------------------------------

 

 

 

 

 

+

TOTAL LINES

: ALLOC =

2750

LARGEST BLOCK =

2496

USED =

238

PHYSICAL LINES: ALLOC =

1368

MAX USED

=

203

USED =

203

+------------------------------------

 

+------------------------------------

 

 

 

 

 

+

 

CONFIGURABLE PARAMETERS

 

 

 

 

+------------------------------------

 

+------------------------------------

 

 

 

 

 

+

ALLOC /MAXUSED/ USED

 

 

ALLOC /MAXUSED/ USED

+------------------------------------

 

+------------------------------------

PRITRUNK:

 

2 /

1 /

1

+

 

 

 

 

 

TRUNK

:

49 /

49 /

27

 

 

T1SPAN

:

 

2 /

2 /

2

+------------------------------------

 

+------------------------------------

 

 

 

 

 

+

 

* = ALLOC-VALUE EXCEEDS ALLOC-RECMAX

 

 

 

 

 

 

 

 

( RECOMMENDED ALLOC-MAXIMUM )

 

FOR THIS SYSTEM TYPE

 

 

 

 

<dis-dimen:ltg;

 

 

 

 

 

 

 

 

 

 

 

 

 

DIS-DIMEN:LTG;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H500: AMO DIMEN STARTED

 

 

 

 

 

 

 

 

 

 

 

 

+

------------------------------------

 

 

 

 

 

 

+

------------------------------------

 

 

 

 

+

 

 

 

NON-CONFIGURABLE PARAMETERS

 

 

 

 

+

------------------------------------

 

 

 

 

 

 

+

------------------------------------

 

 

 

 

+

TOTAL LINES

: ALLOC =

 

2750

 

LARGEST BLOCK =

2496

 

USED =

238

PHYSICAL LINES: ALLOC =

 

1368

 

MAX USED

=

203

 

USED =

203

+

------------------------------------

 

 

 

 

 

 

+

------------------------------------

 

 

 

 

+

 

 

 

 

CONFIGURABLE

PARAMETERS

 

 

 

 

+

------------------------------------

 

 

 

 

 

 

+

------------------------------------

 

 

 

 

+

LTG: 1

 

ALLOC /MAXUSED/ USED

 

LTG: 1

 

ALLOC

/MAXUSED/

USED

+

------------------------------------

 

 

 

 

 

 

+

------------------------------------

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

APILTG

:

32

/

0

/

 

0

LTGIDX

:

400

/

90 /

90

AUTOLTG :

0

/

0

/

 

0

NWCRLTG :

1

/

0 /

0

DHBUFLTG:

0

/

0

/

 

0

*OPTILTG :

72

/

4 /

3

DIG2LTG :

160

/

0

/

 

0

*OPTSTLTG:

72

/

4 /

3

*DIGILTG :

80

/

4

/

 

3

PRTRKLTG:

1

/

1 /

1

DILTG

:

96

/

4

/

 

3

RDTILTG :

18

/

0 /

0

DLPWLTG :

0

/

0

/

 

0

RP120LTG:

0

/

0 /

0

DSLTG

:

255

/ 115 /

115

RP240LTG:

0

/

0 /

0

DTILTG

:

281

/

30

/

30

RP400LTG:

0

/

0 /

0

DTIS0

:

0

/

0

/

 

0

*S0LTG

:

16

/

0 /

0

KSETLTG :

144

/

4

/

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

------------------------------------

 

 

 

 

 

 

+

------------------------------------

 

 

 

 

+

 

* = ALLOC-VALUE EXCEEDS ALLOC-RECMAX

 

 

 

 

 

 

 

 

( RECOMMENDED ALLOC-MAXIMUM )

 

FOR THIS SYSTEM TYPE

 

 

 

 

Jsl

© 2002 Avaya Inc All Rights Reserved

IP Enabling Siemens

 

 

Hicom with Avaya

 

 

MultiVantage Solutions

LPH 11-27-02

 

8

Image 8
Contents Abstract Introduction Avaya S8300/G700 and Siemens HicomEquipment and Software Validated Siemens HicomCable schematic S8300/G700 ConfigurationsSiemens TMDN64P 25 pair amphenol MM710 RJ45MM710 DS1 Circuit Pack Administration Trunk-Group Administration Hicom Configurations Assign trunk Group MembersDisplays System Dimensions Determine If System Has CapacitiesDis-dimen Dis-dimenltgAdding a TNDN64 T-1 Boardadd-bcsu =30=10 Mos=1000 =30000=260 = yesDisplay Board Dis-bcsutmdDisplay Cabinet Dis-bcsutbl TMDN64PNone Add Trunk Group Access CodesAdd-tgacc Add-cop Display Trunk Group Access Codesdis-tgaccAdd COP Class of Parameters Display COT Class of Trunkdis-cot Display COP Class of Parametersdis-copAdd COT Class of Trunkadd-cot Add COS Class of Service VCE Service Module Access VCEAdd-cos Copycos =Classes of SERVICE, Switching Unit VCE Service Module Access VCE Ddte = Dfax =AMO COS Started Number of the Class of Service Added is Display COS Class of Servicedis-cosall PEN =Did Direct Inward Dialing Trunk Srtidx = ? Accunet 64 R Accunet 64 CAccunet Didcr Did Conversion TableATT5E8 AT&T 5ESSSOFTWARE Generic 5E7/8 Modify D-Channel from DefaultCha-tcsu Protocol would be NI2 if using National Isdn NI2 National IsdnDisplay Trunk Membersdis-tscu VerificationConclusion