2Wire g700, s8300 Cable schematic, S8300/G700 Configurations, Siemens TMDN64P 25 pair amphenol

Page 4

Software:

1.Recommended Siemens Hicom 300. Release 9006.5 or newer.

2.Firmware for the boards and phones are included in the core software.

Hardware:

1.TNBN64P and TNDN64 can be programmed to run PRI and NI2.

2.TMDN TMD24 can only be used with PRI.

Board type used is dependant on software and hardware release of the switch.

4. Cable schematic:

Note: A length of 4-wire cable is needed to make the connection to each PRI circuit card. The Pin assignments for each are as follows.

Siemens TMDN64P (25 pair amphenol)

XTIP

pin 16

RTIP

pin 13

XRING

pin 41 RRING

pin 38

MM710 (RJ45)

 

 

 

XTIP

pin 4

RTIP

pin 1

XRING

pin 5

RRING

pin 2

TN464 DS1 (wall field)

XTIP

pin 22 RTIP

pin 23

XRING

pin 47 RRING

pin 48

5. S8300/G700 Configurations:

The following pages are excerpts of an actual system administration session using the Avaya VisAbility™ Software Suite.

DS1 Interface: ISDN maximizes the number of connections between the switches due to the fast processing of calls across that medium. ISDN also allows for Caller ID, Call Tracing, Call Return and many other features. Configure the DS1 form as described below. Select “isdn- pri” for the Signaling Mode, this allows for Facility and Non-facility Associated Signaling. Select “b8zs” for the line coding which is required when running ISDN. Framing Mode should be “ESF” to allow for best signaling quality. Setting the Connect and Interface prompts to “PBX” and “Network” allows the MM710 to have control over glare conditions. This allows the MM710 to have priority over circuit assignment and force the switch on the other end to continue searching for an open B-Channel. All other prompts are default. If using NI-2 (National ISDN–2) change Protocol Version to “b”.

Jsl

© 2002 Avaya Inc All Rights Reserved

IP Enabling Siemens

 

 

Hicom with Avaya

 

 

MultiVantage Solutions

LPH 11-27-02

 

4

Image 4
Contents Abstract Introduction Avaya S8300/G700 and Siemens HicomEquipment and Software Validated Siemens HicomCable schematic S8300/G700 ConfigurationsSiemens TMDN64P 25 pair amphenol MM710 RJ45MM710 DS1 Circuit Pack Administration Trunk-Group Administration Hicom Configurations Assign trunk Group MembersDisplays System Dimensions Determine If System Has CapacitiesDis-dimen Dis-dimenltgAdding a TNDN64 T-1 Boardadd-bcsu =30=10 Mos=1000 =30000=260 = yesDisplay Board Dis-bcsutmdDisplay Cabinet Dis-bcsutbl TMDN64PAdd-tgacc Add Trunk Group Access CodesNone Add COP Class of Parameters Display Trunk Group Access Codesdis-tgaccAdd-cop Add COT Class of Trunkadd-cot Display COP Class of Parametersdis-copDisplay COT Class of Trunkdis-cot Add COS Class of Service VCE Service Module Access VCEAdd-cos Copycos =AMO COS Started Number of the Class of Service Added is VCE Service Module Access VCE Ddte = Dfax =Classes of SERVICE, Switching Unit Display COS Class of Servicedis-cosall PEN =Did Direct Inward Dialing Trunk Srtidx = ? Accunet 64 R Accunet 64 CAccunet Didcr Did Conversion TableCha-tcsu Modify D-Channel from DefaultATT5E8 AT&T 5ESSSOFTWARE Generic 5E7/8 Protocol would be NI2 if using National Isdn NI2 National IsdnConclusion VerificationDisplay Trunk Membersdis-tscu