2Wire s8300, g700 Display Trunk Group Access Codesdis-tgacc, Add COP Class of Parameters, Add-cop

Page 13

CFBLOCK = ?

 

 

CFBLOCK

: CALL FORWARD BLOCKING

CHARACTERISTIC

: OPTIONAL

 

POSSIBLE VALUES : ENABLED

CALL FORWARD BLOCKING ENABLED

 

DISABLED

CALL FORWARD BLOCKING DISABLED

CFBLOCK = DISABLED

 

ADD-TGACC:100,NONE,C-HAWK,23,BOTH,TERR,,,0,ROUND,;

H500: AMO TGACC STARTED

 

H1: TRUNK GROUP

100 HAS BEEN CREATED

AMO-TGACC-111

TRUNK GROUP ACCESS CODE

ADD COMPLETED;

 

 

Display Trunk Group Access Codes:<dis-tgacc

TGRP =100;

 

 

 

 

 

 

 

DIS-TGACC:100;

 

 

 

 

 

 

 

H500: AMO TGACC STARTED

 

 

 

 

 

+-------------------------------------------------------------------------

 

 

 

 

 

+

TGRP NUMBER

:

100

TGRP NAME

: CHAWK

/N

MAXIMUM NO:

23

SUBGROUP NUMBER:

3

DEVICE TYPE: PRI B

 

DIR TYPE : BOTH

ACD THRESHOLD

:

*

TRACENO

:

0

USAGE TYPE: TERR

ALLOCATED TO AT LEAST ONE ROUTE

 

 

GDTR RULE :

0

SELECTION

:

ROUND

CFBLOCK

: DISABLED

 

 

 

 

 

 

 

 

 

 

THE FOLLOWING PORTS (LTG-LTU-SLOT-CIRCUIT) ARE ALLOCATED:

 

 

 

 

 

 

 

 

+-------------------------------------------------------------------------

 

 

 

 

 

+

1-1-73-1 1-1-73-2 1-1-73-3 1-1-73-4 1-1-73-5 1-1-73-6

 

+-------------------------------------------------------------------------

 

 

 

 

 

+

1-1-73-7 1-1-73-8 1-1-73-9 1-1-73-10 1-1-73-11 1-1-73-12

 

+-------------------------------------------------------------------------

 

 

 

 

 

+

1-1-73-13 1-1-73-14 1-1-73-15 1-1-73-16 1-1-73-17 1-1-73-18

 

+-------------------------------------------------------------------------

 

 

 

 

 

+

1-1-73-19 1-1-73-20 1-1-73-21 1-1-73-22 1-1-73-23

 

 

+-------------------------------------------------------------------------

 

 

 

 

 

+

AMO-TGACC-111

 

TRUNK GROUP ACCESS CODE

 

 

 

DISPLAY COMPLETED;

 

 

 

 

 

 

Add COP (Class of Parameters):

<add-cop

COPNO = 100

 

 

 

PAR = ;

 

 

 

ADD-COP:100,;

 

 

 

H500: AMO COP

STARTED

 

H1: COP 100 IS NOW SET UP

 

AMO-COP -111

CLASS OF PARAMETER

 

ADD COMPLETED;

 

 

 

 

 

 

 

 

 

Jsl

 

© 2002 Avaya Inc All Rights Reserved

IP Enabling Siemens

 

 

 

 

Hicom with Avaya

 

 

 

 

MultiVantage Solutions

 

LPH 11-27-02

 

 

13

Image 13
Contents Abstract Avaya S8300/G700 and Siemens Hicom IntroductionSiemens Hicom Equipment and Software ValidatedS8300/G700 Configurations Cable schematicSiemens TMDN64P 25 pair amphenol MM710 RJ45MM710 DS1 Circuit Pack Administration Trunk-Group Administration Assign trunk Group Members Hicom ConfigurationsDetermine If System Has Capacities Displays System DimensionsDis-dimen Dis-dimenltg=30 Adding a TNDN64 T-1 Boardadd-bcsu=10 Mos=30000 =1000=260 = yesDis-bcsutmd Display BoardDisplay Cabinet Dis-bcsutbl TMDN64PAdd-tgacc Add Trunk Group Access CodesNone Add COP Class of Parameters Display Trunk Group Access Codesdis-tgaccAdd-cop Add COT Class of Trunkadd-cot Display COP Class of Parametersdis-copDisplay COT Class of Trunkdis-cot VCE Service Module Access VCE Add COS Class of ServiceAdd-cos Copycos =AMO COS Started Number of the Class of Service Added is VCE Service Module Access VCE Ddte = Dfax =Classes of SERVICE, Switching Unit PEN = Display COS Class of Servicedis-cosallDid Direct Inward Dialing Trunk Srtidx = ? Accunet 64 C Accunet 64 RAccunet Didcr Did Conversion TableCha-tcsu Modify D-Channel from DefaultATT5E8 AT&T 5ESSSOFTWARE Generic 5E7/8 NI2 National Isdn Protocol would be NI2 if using National IsdnConclusion VerificationDisplay Trunk Membersdis-tscu