2Wire s8300, g700 manual Adding a TNDN64 T-1 Boardadd-bcsu, =30, =10, Mos, User

Page 9

Adding a TNDN64 T-1 Board:<add-bcsu

BOARD = ?

 

 

BOARD

: SPECIFY BOARD TYPE

CHARACTERISTIC

: REQUIRED

CONDITIONAL

POSSIBLE VALUES : STMA

STMA

 

SLMN

SLMN USED FOR NX64

 

IPDN

IPDN BOARD USED FOR ISDN APPLICATIONS

 

RPER

ROLM PERIPHERAL BOARDS

 

RT1

ROLM T1 BOARD

 

TMD

DIGITAL TRUNK MODULE WITH 24 CHANNELS

 

RG

RING GENERATOR

 

SIUP

SIGNALLING UNIT PERIPHERY

BOARD = tmd

PER

PERIPHERY MODULE

 

 

LTG = 1

 

 

LTU = 1

 

 

 

 

 

SLOT = 79

q2484-x (part number for a TNDN64P number will vary with hardware)

PARTNO =

FCTID = 2 ???

 

 

 

 

LWVAR = ?

 

 

 

 

 

LWVAR

 

: LOADWARE VARIANT

 

CHARACTERISTIC

: OPTIONAL

 

 

 

POSSIBLE

VALUES : MAX. OF 8 POSITIONS

 

LWVAR =0

1

 

 

 

 

CABTYP =

 

 

 

 

TIMTYP =

?

 

 

 

 

TIMTYP

 

: SPECIFY SYSTEM OR LOOP TIMING FOR TMD24

 

CHARACTERISTIC

: OPTIONAL

 

 

 

POSSIBLE

VALUES : SYST

TMD FRAME TIMING DRIVEN BY SYSTEM

TIMTYP =syst

LOOP

LOOPBACK STATE

 

 

 

 

 

OESDISTH

=30

 

 

 

 

OESREQTH

=4

 

 

 

 

SESDISTH

=10

 

 

 

 

SESREQTH

=10

 

 

 

 

SIGTYP =

?

 

 

 

 

SIGTYP

 

: TYPE OF SIGNALING ON TMD24 SPAN

 

CHARACTERISTIC

: REQUIRED

CONDITIONAL

 

POSSIBLE

VALUES : CVN

CORNET-VN LINK WITH 24 CHANNELS

 

 

 

 

CCO

DMI LINK WITH 24 CHANNELS

 

 

 

 

MOS

DMI LINK WITH MESSAGE ORIENTED SIGNALING

 

 

 

BOS

DMI LINK WITH BIT ORIENTED SIGNALING

 

 

mos

CAS

TMD LINK WITH CHANNEL ASSOCIATED SIGNALING

SIGTYP =

 

 

 

 

NETUSR =

?

 

 

 

 

NETUSR

 

: USER TO EMULATE NETWK OR USER ON DMI LINK

 

CHARACTERISTIC

: OPTIONAL

 

 

 

POSSIBLE

VALUES : USER

USER WILL EMULATE USER END OF DMI LINK

 

 

user

NETWK

USER WILL EMULATE NETWK END OF DMI LINK

NETUSR =

 

 

 

 

 

 

 

 

 

 

 

 

Jsl

 

 

© 2002 Avaya Inc All Rights Reserved

 

IP Enabling Siemens

 

 

 

 

 

 

Hicom with Avaya

 

 

 

 

 

 

MultiVantage Solutions

 

LPH 11-27-02

 

 

 

9

Image 9
Contents Abstract Avaya S8300/G700 and Siemens Hicom IntroductionSiemens Hicom Equipment and Software ValidatedS8300/G700 Configurations Cable schematicSiemens TMDN64P 25 pair amphenol MM710 RJ45MM710 DS1 Circuit Pack Administration Trunk-Group Administration Assign trunk Group Members Hicom ConfigurationsDetermine If System Has Capacities Displays System DimensionsDis-dimen Dis-dimenltg=30 Adding a TNDN64 T-1 Boardadd-bcsu=10 Mos=30000 =1000=260 = yesDis-bcsutmd Display BoardDisplay Cabinet Dis-bcsutbl TMDN64PAdd Trunk Group Access Codes Add-tgaccNone Display Trunk Group Access Codesdis-tgacc Add COP Class of ParametersAdd-cop Display COP Class of Parametersdis-cop Add COT Class of Trunkadd-cotDisplay COT Class of Trunkdis-cot VCE Service Module Access VCE Add COS Class of ServiceAdd-cos Copycos =VCE Service Module Access VCE Ddte = Dfax = AMO COS Started Number of the Class of Service Added isClasses of SERVICE, Switching Unit PEN = Display COS Class of Servicedis-cosallDid Direct Inward Dialing Trunk Srtidx = ? Accunet 64 C Accunet 64 RAccunet Didcr Did Conversion TableModify D-Channel from Default Cha-tcsuATT5E8 AT&T 5ESSSOFTWARE Generic 5E7/8 NI2 National Isdn Protocol would be NI2 if using National IsdnVerification ConclusionDisplay Trunk Membersdis-tscu