Trane PKGP-PRC001-EN manual Jobsite Connections, Zone Sensors -Typical Number Of Wires

Page 33

Jobsite Connections

DISCONNECT

SWITCH

(BYOTHERS)

ZONESENSORS

ROOFTOP

UNIT

Zone Sensors —Typical Number Of Wires

 

A— Manual Changeover

6

Manual/Auto Changeover

7

Manual/Auto Changeover with

 

Status Indication LED’s

10

Programmable Night Setback with

 

Status Indication LED’s

7

B— 3 Power Wires + 1 Ground Wire (three phase) 2 Power Wires + 1 Ground Wire (single phase)

For specific wiring information, see the installation instructions. All wiring except power wires is low voltage.

All customer supplied wiring to be copper and must conform to NEC or CEC and local electrical codes. Wiring shown dotted is to be furnished and installed by the customer.

PKGP-PRC001-EN

33

Image 33
Contents Packaged Heat Pumps Introduction Packaged Rooftop Air ConditionersContents Features Benefits Factory Installed Options Field Installed OptionsFactory or Field Installed Options Features and Benefits Easy to Install, Service and MaintainQuality and Reliability ColoredAnd NumberedWiring Clogged Filter/Fan Failure SwitchPower Exhaust Option Quick-Access PanelsRigorous Testing Added Efficiency Easy to Install and ServiceBarometric Relief Power Exhaust AccessoryCondensate Trap Clearance RequirementsHeating Capacity Cooling CapacityStep To Find Capacity at Intermediate ConditionsDigits 9, 10 Factory Installed Options Model Number DescriptionCapacity MBh Data12½Ton GeneralTable GD-1 General Data EER2Table GD-2 General Data General DataMBH SHC MBH SHC MBH SHC PerformanceData15Ton WC*180BMBH SHC Data20Ton Three Phase WCD240BTable PD-6 Evaporator Fan Performance 12½ Ton WC*150B BHPBHP RPM Table PD-7 Evaporator Fan Performance 15 Ton WCD180B Table PD-8 Evaporator Fan Performance 15 Ton WCH180BCFM RPM BHP RPM BHP Table PD-9 Evaporator Fan Performance 20 Ton WC*240BData12½ 20Tons Table PD-10 Standard Motor & Drive/Fan Speed RPMTable PD-12 Oversized Motor & Drive/Fan Speed RPM WCH240B WCD240BData12½Ton Data15Ton Data20Ton Table PD-20 Auxiliary Electric Heat Capacity Table PD-19- Heating Capacity Correction FactorsControls Field Installed Control OptionsTable ED-1 Unit Wiring Electrical DataRPM FLA LRA 208/230 Volts Three Phase Volts Three Phase WCD150BW AYDHTRKW36A AYDHTRKW18AAYDHTRKW54A AYHHTRNW18AFLA LRA RPM RLA LRA Zone Sensors -Typical Number Of Wires Disconnect Switch Byothers Zonesensors Rooftop UnitJobsite Connections Typical Wiring 12½ 20TonsWiring 12½ 20Tons Wiring 12½ 20Tons Wiring 12½ 20Tons Dimensional Data 12½, 15TonDownflow Unit Clearance Horizontal Unit Supply/Return and Unit Clearance Downflow Duct Connections Field FabricatedDimensional 19 5/16 73 7/16 26 5/16 Table DD-1 Dimensional 12½ 20Tons DataAccessoriesTable DD-2 Options FiopsOptions Fiops Table DD-3 12½-20 Tons Weights 12½ 20Tons Table W-1 Accessory Net Weights LbsTable W-1 Weights 12½ 20Tons Mechanical Specifications Factory Installed Options High Pressure CutoutTwo-Inch Pleated Filters Economizer Downflow Factory or Field Installed OptionsFrostat Reference or Comparative EnthalpyPowered Exhaust Field Installed OptionsManual Outside Air Damper Roof Curb DownflowTrane

PKGP-PRC001-EN specifications

The Trane PKGP-PRC001-EN is a highly efficient and versatile rooftop packaged unit designed for commercial HVAC applications. This advanced system showcases Trane's commitment to quality, reliability, and energy efficiency while catering to a diverse range of climate control needs. Its innovative technologies and features make it a top choice for building owners and facility managers looking to enhance indoor comfort while minimizing energy costs.

One of the standout characteristics of the PKGP-PRC001-EN is its impressive cooling and heating capacities, which ensure optimal performance in various conditions. This unit is equipped with advanced scroll compressors that provide efficient cooling and heating, enabling it to maintain a comfortable environment even during extreme temperature fluctuations. The unit also features a multi-position design, allowing for easy installation and adaptation to different rooftop configurations.

In terms of energy efficiency, the PKGP-PRC001-EN excels with its high Seasonal Energy Efficiency Ratio (SEER) and Energy Efficiency Ratio (EER) ratings. These ratings signify its ability to deliver exceptional cooling performance while consuming less energy, ultimately lowering operational costs for facility owners. Additionally, the unit complies with the latest energy standards, including ASHRAE 90.1 and DOE regulations, further emphasizing its commitment to sustainability.

Another notable feature is its advanced control system. The PKGP-PRC001-EN comes equipped with Trane's proprietary Tracerâ„¢ controls that provide precise temperature and humidity management. These controls are user-friendly, allowing for easy programming and monitoring of the system's performance. Furthermore, the unit can be integrated with building management systems (BMS), offering greater control and efficiency.

The design of the PKGP-PRC001-EN also emphasizes durability and ease of maintenance. Constructed with high-quality materials, this unit withstands harsh environmental conditions while minimizing wear and tear over time. Access panels and a structured layout allow for straightforward maintenance, ensuring that service and repairs can be conducted quickly and efficiently.

In summary, the Trane PKGP-PRC001-EN is more than just an HVAC unit; it is a comprehensive solution for efficient heating and cooling in commercial settings. With its cutting-edge technologies, energy-efficient performance, and user-friendly control capabilities, this rooftop packaged unit is an excellent choice for those looking to optimize their HVAC operations while embracing sustainability and reliability.