DANGER
LEAK TESTING:
To prevent fire or explosion hazard:
•DO NOT smoke or permit ignition sources in the area while conducting a leak test.
•Perform test OUTDOORS only in a well ventilated area.
•Never perform a leak test with a match or open flame.
•Never perform a leak test while the grill is in use.
WARNING
WHEN TO PERFORM A LEAK TEST:
•After assembling your grill and before lighting for the first time, even if purchased fully assembled.
•Every time the LP gas cylinder is refilled or if any of the gas components are replaced.
•Any time your grill has been moved.
•At least once per year or if your grill has not been used for more than 60 days.
CHECKING FOR LEAKS:
1.Create a mixture of 50% water and 50% liquid dishwashing soap.
2.Open the lid.
3.Insure the burner knob is set to the OFF position.
4.Turn on the fuel supply at the LP cylinder valve.
Turn the cylinder valve knob one turn counterclockwise.
5.Apply the soap water mixture to the following:
A | Supply tank (cylinder) weld |
|
B Connection nut to tank valve. |
| |
C | Back side of connection nut to brass |
|
| nipple. | F |
|
|
DBrass nipple connection into regulator.
ERegulator connections to gas supply hoses.
FGas supply hose connection to burner valve assembly.
GBurner valve stem cap.
HBurner orifice fitting.
IThe full length of gas supply hose
JTank valve to cylinder
Watch For Bubbles
G
H
E
I
J
D
C
B A
7