WARNING
FILLING THE LP GAS CYLINDER:
•Allow only qualified LP gas dealers to properly fill or repair your LP gas cylinder.
•New tanks should be purged prior to filling; inform LP gas dealer if you are using a new tank.
•DO NOT allow the cylinder to be filled beyond 80% capacity.
•Always use a protective cylinder cap when grill is not connected to cylinder.
•If you exchange a cylinder with a qualified exchange program, be sure the cylinder has a Type 1 valve and an
INSTALLING THE LP GAS CYLINDER ONTO THE GRILL:
1. Check that the cylinder valve is closed by turning the knob clockwise.
2.Place the cylinder onto the bottom shelf/tank support.
3.Orient the cylinder such that the valve opening does not kink or damage the supply hose.
HOSE AND REGULATOR:
Your grill is equipped with a Type 1 connection device with the following features:
HIGH
IGNITER
LOW
•Refer to owner's manual for match lighting | |||
procedure. | |||
• | For asisstance, call | ||
• | Turn off LP gas cylinder after each use. | ||
|
|
|
|
|
|
|
|
1.The system will not allow gas flow from the cylinder until a positive connection to the valve has been made. NOTE: The cylinder valve must be turned off before any connection is made or removed.
2.A thermal device that will shut off the gas flow if the device is subject to temperatures above 240°F and 300°F (115°C and 150°C). If this should happen, remove the entire regulator assembly and throw it away. A replacement regulator assembly can be purchased by contacting Brinkmann at
The cause of the excessive heat should be determined and corrected before using your grill again.
3.A flow limiting device, when activated, restricts the flow of gas to 10 cubic feet per hour.
5