1.1 Overview

The Teledyne Analytical Instruments (TAI) Model 3300ZB is a microprocessor-based trace oxygen analyzer for real-time measurement of trace amounts of oxygen in inert gases, or in a wide variety of gas mixtures. It features simple operation, fast response, and a compact, rugged construction.

1.2 Main Features of the Analyzer

The main features of the analyzer include:

High resolution, accurate readings of oxygen content from 0-10 parts per million (ppm) through 0-1,000 ppm. Large, bright, light-emitting-diode meter readout

Simple pushbutton controls

Advanced zirconium oxide measuring technology sensors

Fast response and recovery time

Microprocessor based electronics: 8-bit CMOS with on-board RAM and 16 KB ROM

Two user selectable ranges (depending on sensor configuration) allow best match to user’s process and equipment

Operator can select auto-ranging, allowing the analyzer to automatically select the proper preset range for a given measurement or lock the analyzer onto a single range

Two concentration alarms with adjustable set-points

Three analog outputs: two for measurement (0–10 VDC and negative ground 4–20 mADC) and one for range identification (0-10 VDC).

Teledyne Analytical Instruments

1

Image 11
Contents Model 3300ZB Model 3300ZB Safety Messages Model 3300ZB Table of Contents Maintenance Front Panel List of Figures Combustible GAS Usage This page intentionally left blank Page Overview Main Features of the AnalyzerIntroduction Front Panel Front Panel Description∙ Measurement Parameters Readout Rear Panel Description Power Connection Principles of Operation Operational TheoryIntroduction Zirconium Oxide SensorsGeneral ElectronicsEffect of Pressure Block Diagram of the Signal Processing Electronics Signal ProcessingOperational Theory Model 3300ZB Unpacking the Analyzer InstallationElectrical Connections Control Unit InstallationLocation and Mounting Rear Panel Electrical Connectors Contact ID for Failsafe Relay Operation Gas Connections Piping Diagram Installation ChecklistOperation Front Panel Controls and IndicatorsSetting the Analysis Ranges Using the Function and Data Entry ButtonsHI Range Setting the Alarm SetpointsHI Alarm LO AlarmCalibration Sensor Fail AlarmSelecting a Fixed Range or Autoranging LED Display on StartUp This page intentionally left blank Replacing the Fuse MaintenanceWhen to Replace a Sensor Sensor Installation or ReplacementZrO2 Sensor and Cell Block This page intentionally left blank Appendix SpecificationsTeledyne Analytical Instruments Spare Parts ListDrawing List