Teledyne 3300ZB operating instructions Rear Panel Description, ∙ Measurement Parameters Readout

Page 13

Trace Oxygen Analyzer

Introduction

 

 

 

Set LO Alarm Set the concentration BELOW which

an alarm activates.

Set HI Range Set the high analysis range for the instrument (up to 0-1,000 ppm).

Set LO Range Set the low analysis range for the instrument (down to 0-1,000 ppm).

Span Span-calibrate the analyzer.

Data Entry Keys: Two pushbutton membrane switches are used to manually change measurement parameters of the instrument as they are displayed on the LED meter readout:

Up Arrow Increment values of parameters upwards as they are displayed on the LED readout.

Down Arrow Increment values of parameters downwards as they are displayed on the LED readout.

Digital LED Readout: The digital display is a LED device that produces large, bright, 7-segment numbers that are legible in any lighting environment. It has two functions:

Meter Readout

As the meter readout, it displays the oxygen concentration currently being measured.

Measurement Parameters Readout

It also displays user-definable alarm set- points, ranges, and span calibration point when they are being checked or changed.

1.4 Rear Panel Description

The rear panel contains the electrical input and output connectors. Separate rear panel illustrations are shown in Figure 1-2 for the AC and DC powered versions of the instrument. The connectors are described briefly here and in detail in the Chapter 3 - Installation.

Teledyne Analytical Instruments

3

Image 13
Contents Model 3300ZB Model 3300ZB Safety Messages Model 3300ZB Table of Contents Maintenance Front Panel List of FiguresCombustible GAS Usage This page intentionally left blank Page Introduction Main Features of the AnalyzerOverview Front Panel Front Panel Description∙ Measurement Parameters Readout Rear Panel Description Power Connection Introduction Operational TheoryZirconium Oxide Sensors Principles of OperationEffect of Pressure ElectronicsGeneral Block Diagram of the Signal Processing Electronics Signal ProcessingOperational Theory Model 3300ZB Unpacking the Analyzer InstallationLocation and Mounting Control Unit InstallationElectrical Connections Rear Panel Electrical Connectors Contact ID for Failsafe Relay Operation Gas Connections Piping Diagram Installation ChecklistOperation Front Panel Controls and IndicatorsSetting the Analysis Ranges Using the Function and Data Entry ButtonsHI Alarm Setting the Alarm SetpointsLO Alarm HI RangeSelecting a Fixed Range or Autoranging Sensor Fail AlarmCalibration LED Display on StartUp This page intentionally left blank Replacing the Fuse MaintenanceWhen to Replace a Sensor Sensor Installation or ReplacementZrO2 Sensor and Cell Block This page intentionally left blank Appendix SpecificationsTeledyne Analytical Instruments Spare Parts ListDrawing List