FX-301
SPECIFICATIONS
Fibers
Item
Allowable bending radius
Ambient temperature
Ambient humidity
Fiber core
Sheath
Material
Fiber head
Accessories (Note 2)
Type | | | Special use | | |
| Ultra-small diameter | | Fixed-focus reflective | | Tough flexible |
| FT-E12/E22: R5 mm R0.197 in or more (Note 1) | | R10 mm R0.394 in or more | | |
| FD-E12: R10 mm R0.394 in or more (Note 1) | | | R10 mm R0.394 in or more |
| | (FD-L43: R4 mm R0.157 in or more) | |
| FD-E22/EN500S1/ENM1S1: R25 mm R0.984 in or more (Note 1) | | | |
| | | | |
| FT-E12/E22, FD-E22:40 to 70 °C 40 to 158 °F | | FD-L43: 0 to 70 °C 32 to 158 °F | | 40 to 60 °C 40 to 140 °F |
| FD-E12: 40 to 60 °C 40 to 140 °F | | FD-L41/L42: 40 to 60 °C 40 to 140 °F | |
| | | (FD-P81X: 40 to 70 °C 40 to 158 °F) |
| FD-EN500S1/ENM1S1:20 to 60 °C 4 to 140 °F | | FD-L4: 40 to 70 °C 40 to 158 °F | |
| | | |
| 35 to 85 %RH (No dew condensation or icing allowed) |
| | | Acrylic | | |
| Polyolefin | | Polyethylene (FD-L42: Vinyl chloride) | | Polyethylene [FT-P81X: Vinyl chloride, |
| | |
| | | Protective tube: Stainless steel (SUS)] |
| | | | |
| | | FD-L43/L41: Heat-resistant ABS | | |
| Brass (Nickel plated) | | FD-L4: ABS | | FT-P81X, FD-P81X: Brass (Nickel plated) |
| | FD-L42: Aluminum (Black ALMITE) | |
| [Sleeve: Stainless steel (SUS)] | | | FD-G6X: Stainless steel (SUS) |
| | Lens of FD-L43/L4: Acrylic | |
| | | | |
| | | (Front film of FD-L41: Polyester ) | | |
| All fibers: 1 fiber attachment set | | All fibers: 1 fiber attachment set and | | All fibers: 1 fiber attachment set , nuts 2 |
| | FX-CT2(fiber cutter) 1 pc. | | pcs. (thru-beam type: 4 pcs.) and toothed |
| Threaded head fibers: Nuts 2 pcs. and | | |
| | FD-L4: M2.6 (length 12 mm 0.472 in) | | lock washer 1 pc. (thru-beam type: 2 pcs.) |
| toothed lock washer 1 pc. | | screws with washers 2 pcs. and nuts 2 pcs. | | FD-G6X: FX-CT2(fiber cutter) 1 pc. |
| | | |
| | | | | |
Notes: 1) Sleeve part cannot be bent.
2)The five types of attached fiber attachments (FX-AT2/AT3/AT4/AT5/AT6) described in this catalog are for use only with the FX-301/311series. Refer to p.82 for details ‘FIBER OPTIONS’. Fiber attachment accessories are also supplied along with conventional amplifiers. Please contact our office for more details on these accessories.
| | Type |
Item | Model No. |
Allowable bending radius |
Ambient temperature |
Ambient humidity | |
Material | Fiber core | |
Sheath | |
| |
| Fiber head | |
| |
Accessories (Note 2) |
| | |
| Special use |
Liquid level sensing |
FD-F8Y | | FD-F4/F9 |
Protective tube: R40 mm R1.575 in or more | | R10 mm R0.394 in or more |
Fiber: R15 mm R0.591 in or more | |
| |
40 to 125 °C 40 to 257 °F (Note 1) | | 40 to 100 °C 40 to 212 °F (Note 1) |
35 to 85 %RH (No dew condensation or icing allowed)
Polycarbonate
| Polypropylene | Polyethylene |
| |
| Polyetherimide |
| (Protective tube: Fluorine resin) |
| (Lens: Polycarbonate) |
| |
| 1 fiber attachment set | 1 fiber attachment set, FX-CT2(fiber cutter) 1pc. |
| FX-CT2(fiber cutter) 1 pc. | Tying bands 4 pcs., anti-slip tubes 2 pcs. |
| | |
Notes: 1) With the liquid sensing fiber, make sure that the temperature of the liquid is also within the ambient temperature range.
2)The five types of attached fiber attachments (FX-AT2/AT3/AT4/AT5/AT6) described in this catalog are for use only with the FX-301/311series. Refer to p.82 for details ‘FIBER OPTIONS’. Fiber attachment accessories are also supplied along with conventional amplifiers. Please contact our office for more details on these accessories.
| | | | | | | Environment resistant | |
| | Type | | Heat-resistant | | | Chemical-resistant | Vacuum |
| Item | 350 °C 662 °F type | 300°C 572°F type | 200°C 392°F type | 180°C 356°F type | 130°C 266°F type |
| | |
| Allowable bending radius | | R25 mm R0.984 in or more | | R30 mm R1.181 in or more | R200 mm R7.874 in or more |
| (FT-H20W-: R10 mm R0.394 in or more, Sleeve of a head with sleeve: R10 mm R0.394 in or more) | (FT-Z802Y: R25 mm R0.984 in or more) | (FT-60V: R30 mm R1.181 in or more) |
| | |
| | | 60 to 350 °C | 60 to 300 °C | 60 to 200 °C | | 60 to 180 °C | 60 to 130 °C | 40 to 115 °C | 40 to 120 °C |
| Ambient temperature | 76 to 662 °F | 76 to 572 °F | 76 to 392 °F | | 76 to 356 °F |
| | | (Note 1, 2) | (Note 1, 2, 3) | (Note 2) | | (Note 2, 4) | 76 to 266 °F | 40 to 239 °F | 40 to 248 °F |
| | | | | (FT-Z802Y: 0 to 60 °C 14 to 140 °F) | |
| Ambient humidity | | | 35 to 85 %RH (No dew condensation or icing allowed) | |
| | Fiber core | Multi-component glass (Note 3) | | Silicone | | Acrylic | Quartz glass (Note 3) |
| | | | | Silicone | | | | | |
| | | | | Inside stainless steel | | | | | |
| Material | | | | (SUS) spiral tube | | | | | |
| Sheath | | | FD-H20-21: | | Fluorine resin | | Fluorine resin |
| | Stainless steel (SUS) | Stainless steel (sus) | | | | Protective tube: Fluorine resin | |
| | FT-H20W-: | | | | |
| | | | | | | |
| | | | | | | | |
| | | | | Fluorine resin | | | | Sheath: Polypropylene | |
| | Fiber head | | | Brass (Nickel plated) | | Stainless steel (SUS) | Brass (Nickel plated) | (Sheath of FT-Z802Y: Fluorine resin) | Aluminum |
| | | | | |
| | | | | FD-H20-21:Stainless steel (sus) | | | | | |
| | | FT-H20W-, FD-H18-L31and FT-H13-FM2: 1 fiber attachment set | | Nuts 2 pcs. (thru-beam type: 4 |
| Accessories (Note 5) | Free-cut type fibers: FX-CT2(fiber cutter) 1 pc. | | 1 fiber attachment set | pcs.) and toothed lock washer |
| | | Threaded head fibers: Nuts 2 pcs. (thru-beam type: 4 pcs.) and toothed lock washer 1 pc. (thru-beam type: 2 pcs.) | FX-CT2(fiber cutter) 1 pc. | 1 pc. (thru-beam type: 2 pcs.) |
Notes: 1) If the fiber is used below 30 °C 22 °F, its maximum resistable temperature drops to 200° C 392 °F. If the side-view lens FX-SV1is put on the fiber head, the allowable maximum temperature drops to 300 °C 572 °F. (The ambient temperature range of FX-SV1is from 60 to 300 °C 76 to 572 °F.)
2)The ambient temperature of heat-resistant 350 °C 662 °F type, 300 °C 572 °F type, 200 °C 392 °F type and 180 °C 356 °F type fibers are the value in dry condition. In humid environment, the ambient temperature differs. (For a high humidity of 85 %RH, the ambient temperature is 0 to 40 °C 14 to 104 °F.)
3)If the fiber material is quartz glass or multi-component glass, keep it away from vibration or impact.
4)The normal temperature for continuous usage or storage should be 60 to 150 °C 76 to 302 °F.
5)The five types of attached fiber attachments (FX-AT2/AT3/AT4/AT5/AT6) described in this catalog are for use only with the FX-301/311series. Refer to p.82 for details ‘FIBER OPTIONS’. Fiber attachment accessories are also supplied along with conventional amplifiers. Please contact our office for more details on these accessories.