Connector:  | |
  | 360808 or equivalent  | 
Cable Specifications  | 
  | 
Wire Type:  | .5mm or 24 AWG twisted pairs  | 
Maximum Cable Length:  | 100 meters (328 ft.) with standard  | 
  | receiver squelch levels  | 
Cable Loss:  | Must be ≤ 11.5 dB/100 m for fre-  | 
  | quency range of   | 
Characteristic Impedance  | |
  | |
Propagation Delay:  | ≤ 5.7 nanoseconds/meter  | 
Cabling:  | RJ45 plug to RJ45 plug straight  | 
  | through for multiport repeater  | 
  | applications (Transmit to Receive  | 
  | crossover cable for   | 
  | work)  | 
10Base-2  (BNC)
  | Pin | Function | 
  | 
  | Center  | Signal | 
  | 
  | Shield | Isolated GND | 
  | 
  | 
  | 
  | 
  | 
Data Transfer Rate:  | 10 Mbps  | ||
Accessing Scheme:  | CSMA/CD (Carrier Sense Multiple  | ||
  | 
  | Access with Collision Detection)  | |
Topology: | Bus  | ||
Maximum Nodes:  | 30  | 
  | |
Transmission Medium:  | Coaxial cable  | ||
Network Lobe Distance:  | Minimum separation of .5 meters  | ||
Connector:  | Type BNC “T”  | ||