USRobotics NETServer/16 IPX Configuration, Ethernet802.3 ethernet802.2 ethernet802.2II ethernetII

Models: NETServer/16 NETServer/8

1 284
Download 284 pages 20.7 Kb
Page 25
Image 25

IPX Configuration

IMPORTANT: Even if your network uses only the IPX protocol, you must set up an IP address for the NETServer if you want to use the Windows-based management software. If you have not already done so, perform step 1 under IP Configuration.

1.IPX Network Frame Type: This is the IPX frame type of the network segment connected to the NETServer’s LAN port.

set net0 ipxframe <frame type>

Enter

Valid frame types are:

ethernet_802.3 ethernet_802.2 ethernet_802.2_II ethernet_II

Example:

set net0 ipxframe ethernet_II

Enter

2.IPX Network Number: This is the network number of the network segment connected to the NETServer’s LAN port. Note that the same physical network segment will have a different network number for each frame type used. Be sure to select the network number associated with the frame type selected above. Type the following:

set net0 ipxnet <network number>

Enter

<Network Number> is the number you obtained by follow- ing the instructions titled First Step for IPX Networks. If you have not already obtained this number, do so now.

Example:

set net0 ipxnet 00000684

Enter

Note that the preceding 0’s in this example could have been omitted. The NETServer would have accepted “684” as the correct IPX Network Number and filled in the preceding 0’s.

Basic Installation 2-9

Page 25
Image 25
USRobotics NETServer/16, NETServer/8 manual IPX Configuration, Ethernet802.3 ethernet802.2 ethernet802.2II ethernetII