DATE & TIME SET PROCEDURE

1.To adjust the date/time, press the Set button.

2.The display will show a blinking number showing the date. Change the month by pressing the button. Each press will increase the number by one

in a cycling manner. Press the Set button again to confirm the entry, and the screen will show a blinking number representing the day of the month.

3.Change the date and time as described in Step 2

above, using the button to change the numbers and the Set button to confirm the entries.

Press thebutton

blinking month

increasing month confirm the entry repeat process to set date and time

13

USING THE ARM CUFF

Very Important: Proper cuff size is critical to accurate measurement.

This monitor comes with a Standard Size arm cuff that fits arms with circumferences of 9”–13” (23 cm – 33 cm).

This cuff is suitable for your use if the colored arrow falls within the solid color line as shown below.

If the arrow falls outside of the solid color line, you will need a cuff with another circumference. Contact HoMedics Consumer Relations at 1-800-466-3342.

Colored Arrow

 

 

 

FALL

BAND

 

 

 

 

ARROW MUST

WITHIN YELLOW

Position cuff

 

 

 

edge 0.6˝–1.0˝

 

 

 

(1.5–2.5cm) above elbow.

 

 

 

 

 

 

UST

FALLBAND

 

 

 

M

 

 

 

A RROWHIN

 

Y ELLOW

Center tube over

Fit cuff securely. Allow room for

 

 

 

middle of arm.

two fingers to fit between the cuff

WIT

 

 

 

 

and your arm.

 

 

 

 

 

MODEL# PP-BPCUFF5

 

 

 

 

Center tube over

 

 

 

 

 

middle of arm

 

Solid Colored Line

14

BPS-060_B.indd 15-16

5/01/10 1:27 PM

Image 8
Contents Manual Inflate Blood Pressure Monitor Table of Contents Important Product Notices and Safety Instructions About Blood Pressure HOW this Blood Pressure Monitor Works NAME/FUNCTION of Each PartDisplay Symbols Display ExplanationsInstalling Batteries Replace the batteries ifDate & Time SET Procedure Using the ARM CuffPlug the cuff tube into the left side of the unit Measurement Procedure Important NotesMeasurement is then automatically stored into memory Clearing Values from Memory Risk Category IndexRecalling Values from Memory CARE, Maintenance & Cleaning Important Notes Regarding Your Blood Pressure MeasurementPotential for Electromagnetic Interference Troubleshooting SpecificationsMonitor de Presión Sanguínea de Inflado Manual Información DE USO ÍndiceInformación Inicial Avisos Importantes DEL Producto Instrucciones DE Seguridad Sobre LA Presión Sanguínea Cómo Funciona Este Monitor DE Presión Sanguínea NOMBRE/FUNCIÓN DE Cada PiezaExplicaciones DE LA Pantalla Símbolos de la pantallaProcedimiento DE Configuración DE Fecha Y Hora Instalación DE LAS PilasUSO DEL Brazalete Flecha de ColorProcedimiento DE Medición NotaPara interrumpir la medición, puede presionar los botones Cómo Borrar LOS Valores DE LA Memoria Índice DE Categoría DE RiesgoCómo Recuperar LOS Valores DE LA Memoria CUIDADO, Mantenimiento Y Limpieza Potencial DE Interferencia Electromagnética Diagnóstico Y Resolución DE Problemas EspecificacionesDistribuido por