1.With the cuff wrapped around your arm, press the START/ STOP button. Do not inflate the cuff unless it is wrapped around your arm. All digits will light up to check the display functions. The checking procedure will be completed after about 3 seconds. The ( ) arrow will appear momentarily and then the display will show a “00”. The monitor is “Ready to Measure” at this point.

2.Using the hand of the arm that does not have the cuff on it (this will be your right hand if wearing the cuff on your left arm), squeeze the inflation bulb and continue pumping until the pressure reading on the display reaches 140 mmHg. The cuff will then begin slowly deflating as part of the measurement process.

If the pressure in the cuff is not enough, an upward arrow () will appear, directing you to continue pumping. It is recommended that you pump until the downward arrow () appears.

3.When the measurement is completed, the cuff will deflate entirely. Systolic pressure, diastolic pressure and pulse will be shown simultaneously on the LCD screen.

The measurement is then automatically stored into memory.

Note:

1.This monitor automatically turns off approximately 1 minute after last operation. You may also press the START/STOP button to turn the unit off.

2.To interrupt the measurement, you may press the START/STOP button (recommended), “MEM”, or

Date/Time Set buttons. The cuff will deflate immediately after a button is pressed.

19

BPS-060_B.indd 21-22

20

5/01/10 1:27 PM

Image 11
Contents Manual Inflate Blood Pressure Monitor Table of Contents Important Product Notices and Safety Instructions About Blood Pressure NAME/FUNCTION of Each Part HOW this Blood Pressure Monitor WorksDisplay Explanations Display SymbolsReplace the batteries if Installing BatteriesUsing the ARM Cuff Date & Time SET ProcedurePlug the cuff tube into the left side of the unit Important Notes Measurement ProcedureMeasurement is then automatically stored into memory Clearing Values from Memory Risk Category IndexRecalling Values from Memory Important Notes Regarding Your Blood Pressure Measurement CARE, Maintenance & CleaningPotential for Electromagnetic Interference Specifications TroubleshootingMonitor de Presión Sanguínea de Inflado Manual Información DE USO ÍndiceInformación Inicial Avisos Importantes DEL Producto Instrucciones DE Seguridad Sobre LA Presión Sanguínea NOMBRE/FUNCIÓN DE Cada Pieza Cómo Funciona Este Monitor DE Presión SanguíneaSímbolos de la pantalla Explicaciones DE LA PantallaInstalación DE LAS Pilas Procedimiento DE Configuración DE Fecha Y HoraFlecha de Color USO DEL BrazaleteNota Procedimiento DE MediciónPara interrumpir la medición, puede presionar los botones Cómo Borrar LOS Valores DE LA Memoria Índice DE Categoría DE RiesgoCómo Recuperar LOS Valores DE LA Memoria CUIDADO, Mantenimiento Y Limpieza Potencial DE Interferencia Electromagnética Especificaciones Diagnóstico Y Resolución DE ProblemasDistribuido por