Lumiscope 6700 user manual Automatic Valve System, Maintenance

Page 13

3.The aerosol flow rate can be regulated by adjusting the flow rate controller as shown at

right. The recommended practice, especially for children, is to set to the "Minimum" po- sition in order to promote the deposit of the nebulized aerosol directly in the airways.

4.Once the mist generated is no longer constant, it means the medication in the medica-

tion cup is running out; but continue the therapy until there is no aerosol at all.

Note: At the end of inhalation therapy, a small amount of the medication (about 0.4 ml) will remain in the medication cup; this is normal. This portion of the medication, called the "residual volume", cannot be nebulized.

5.Disconnect the plug from the device's power socket.

Automatic Valve System

The device's mouthpiece has a two-valve system to ensure maximum efficiency of the inha- lation and to minimize medication waste. In practice, the mouthpiece expiration valve will open during expiration, allowing the patient's exhaled air to pass to atmosphere, avoiding contamination of the device. During inspiration, the valve will close, maximizing the inhala- tion amount.

MAINTENANCE

WARNING: To reduce the risk of burns, electrocution, fire, or personal injury:

1.Electrical shock hazard - do not remove the outer case of the device.. All disassembly and maintenance of the device must be performed by a qualified service technician.. Refer service to qualified service personnel..

2.This device does not require oil.. Do attempt to lubricate any internal parts..

3.Unplug this device before cleaning.. Do not submerge in water for cleaning..

13.. .

6700-INS-LAB-RevA08.indd 13

1/27/09 4:58 PM

Image 13
Contents Portable Ultrasonic Nebulizer Model Index Contents Operation & Indication PartsIntroduction Important Safety PrecautionsIntended use INS-LAB-RevA08.indd 27/09 458 PM INS-LAB-RevA08.indd 27/09 458 PM Setup INS-LAB-RevA08.indd 27/09 458 PM With the AC/DC Adapter Method of PoweringWith the Optional Car Adapter Cigarette Lighter With the Optional Rechargeable Battery Inhalation Therapy OperationAutomatic Valve System MaintenanceCleaning the Nebulizer Daily Cleaning the Nebulizer After Each UseReplacing the Medication Cup Storage Replacing the Air FilterProtection against incorrect Power Supply Safety ProtectionsTechnical Specifications Protection Against OverheatingLimited Warranty Accessories IncludedRepair Department Distributed by Nebulizador Portable Ultrasonido Modelo Manual Usuario Index Contenidos Operación & Indicaciones PartesUso entendido IntroducciónPrecauciones DE Seguridad Importante Peligro Para reducir el riesgo de electrocución Advertencia Para EL USO DE Medicamentos Montaje INS-LAB-RevA08.indd 27/09 458 PM Con el Adaptador de AC/DC Método DE PrendiendoCon el Adaptador de Carro Encendedor de Cigarillo Opcional Con la Batería Recargable Opcional Terapia de Inhalación OperaciónMantenimiento Sistema de Válvula AutomáticoLimpiando el Nebulizador Al Diario Limpiando el Nebulizador Después de Cada UsoReemplazando la Taza de Medicamento Almacenaje Reemplazando el Filtro de AireProtección sobre Suministro de Electricidad Incorrecto Precauciones DE SeguridadProtección Sobre Recalentarse Especificaciones TécnicasGarantía Limitada Accesorios IncluidosDepartamento de Reparación Distribuido por